6 Reasons Saudi Buyers Choose pipingmaterial.sa for Power Cables ?
Same-Day Response
Inquiry Matched Within Hours
Multiple Supplier Quotes
Compare & Pick the Best Price
SEC & ARAMCO Approved
Pre-Verified Cable Vendors
IEC/BS Test Reports
ILAC • SASO • IECEE Docs
Ex-Stock in Saudi Arabia
Riyadh • Dammam • Jeddah
Zero Commission Model
Direct Contact • No Markup
Power Cable Overview
  • Standards: IEC 60502, BS 5467, BS 6346, IEC 60227
  • Cable Types: Single Core, Multi Core, Armoured, Unarmoured
  • Conductor: Copper & Aluminium
  • Insulation: XLPE, PVC, EPR, LSOH
  • Voltage Range: 0.6/1 kV up to 33 kV
  • Core Range: 1 Core to 5 Core
  • Sizes Available: 1.5 mm² to 1000 mm²
  • Sheathing: PVC Inner/Outer, HDPE, LSZH
  • Armouring: SWA, AWA, DSTA, STA
  • Test Reports: ILAC-Accredited Labs, IECEE
  • HSN Code: 8544
  • Origin: India, Turkey, China, Germany, Saudi Arabia
Power Cable Suppliers in Saudi Arabia

Get Verified Power Cable Suppliers in Saudi Arabia

Buy SEC Approved Single and Multi Core Electrical Wire Stock At Factory Price, Refer Armouring Types

pipingmaterial.sa Connects You Across Saudi Arabia Directly With Genuine Power Cable Stockists In Riyadh, Dammam, Jubail, And Jeddah. We Entirely Eliminate Middlemen and Connect You With Multiple Competitive Offers Carrying Full IEC-Compliant Documentation, Guaranteed Delivery Schedules, and Zero Commission On Our End. From Single Core Cables to AYY/YY Multi Core Shielded Power Cables, Every Product Meets SASO And IEC 60502 Need, Send Your Complete Specification To contact@pipingmaterial.sa Right Now

Supplied To:
Riyadh Dammam Jeddah Al Jubail Al Khobar Yanbu Tabuk Ras Al-Khair Rabigh Dhahran Mecca Medina
Provides:
IEC 60502 Certified BS 5467 / BS 6346 SASO Compliant SEC Approved Ex-Stock Saudi Arabia ILAC Lab Test Reports

Heavy Duty Power Cable Armouring Types

SWA - Steel Wire Armour
AWA - Aluminium Wire Armour
DSTA - Double Steel Tape Armour
STA - Single Steel Tape Armour
Non-Armoured (NAYY/NYY)

Power Cable Specifications

Your Single Inquiry On Pipingmaterial.sa Connects You With Multiple Verified Power Cable Stockists in Saudi Arabia Without Middlemen At Real Prices.

Conductor Sizes
  • 1.5 to 1000 mm²
  • Copper & Aluminium
  • Solid or Stranded
  • Class 1, 2, 5 & 6
Voltage Ratings
  • LT: 0.6/1 kV
  • MV: 3.8/6.6 kV to 8.7/15 kV
  • MV: 12.7/22 kV to 19/33 kV
  • HV: 64/110 kV & above
Core Configuration
  • Single Core
  • 2 Core & 3 Core
  • 3.5 Core & 4 Core
  • 5 Core Multi Core
Insulation Material
  • XLPE
  • PVC
  • EPR
  • LSOH / LSZH
Armouring Types
  • SWA: Steel Wire Armour
  • AWA: Aluminium Wire
  • DSTA: Double Steel Tape
  • STA: Single Tape Armour
Outer Sheath
  • PVC ST1 / ST2
  • HDPE
  • LSZH / LSOH
  • Flame-Retardant
Testing Standards
  • IEC 60502-1 & -2
  • BS 5467 / BS 6346
  • IEC 60332 Flame Test
  • IEC 60754 Halogen Free
Cable Documentation
  • Factory Test Certificate
  • Drum Length Report
  • ILAC Lab Test Report
  • SASO Conformity Cert.
Drum & Packaging
  • Non-returnable Wooden Drum
  • 100 m, 200 m, 500 m Rolls
  • Cut-to-length on Order
  • Custom Drumming Available

Power Cable Types As Per Construction

Power Cable Stockists in Saudi Arabia On Our Platform Maintain Ready Inventory Across All Core Configurations, Voltage Grades, and Armour Types

Single Core Power Cable
Single Core Power Cable
Multi Core Power Cable
Multi Core Power Cable
Shielded Power Cable
Shielded Power Cable
SWA Armoured Power Cable
SWA Armoured Power Cable
Medium Voltage Power Cable
Medium Voltage Power Cable
Heavy Duty Electrical Wire
Heavy Duty Electrical Wire
High Heat Electrical Wire
High Heat Electrical Wire
Fire Resistant Power Cable
Fire Resistant Power Cable

Design Parameters Of AYY/YY-2 Core Power Cables

Cross Sectional Area NominalConductor Min. Number of StrandsApprox. Overall Dia(mm)Inner Sheath Min Thickness in mmInsulation Nominal Thickness in mm Outer Sheath Nominal Thickness in mmApprox. Net Weight Of Cables (Kg/Km)
CUALCables YY CU Cables AYY AL
61/71170.031.001.08370300
41/7-140.031.001.08290240
1061180.031.001.08520400
2566190.031.022.00750450
1666170.031.001.08630430
3566210.031.022.00980550
701212260.031.042.001700850
5066240.031.042.001300700
951515300.041.062.0223001150
1501815340.041.082.0434501600
1201815320.041.062.0228001300
1853030380.052.002.0443002000
5005353540.073.003.04110004800
3003430460.062.042.0867003000
2403430420.052.022.0655002500
4005353520.072.063.0287503800
6305353650.073.043.08138006000

Get Copper and Aluminium Conductor Heavy Duty Power Cable Stockists in Riyadh With Various Insulation

Copper vs Aluminium Conductor Materials

Copper Conductor Cable

  • Electrical Conductivity is 58 MS/m
  • It has Excellent Flexibility Cl. 5 & 6
  • Use in LT, Industrial, Control.Shielded
  • Saudi Market Prefer For LT Installations & Panel Wiring
  • It has Low Oxidation Risk

Aluminium Conductor Cable

  • Electrical Conductivity is 35 MS/m
  • It has Good Flexibility Cl. 1 & 2
  • Use in Overhead Feeders, MV/HV Distribution
  • Its Prefer in MV Grid Cables & SEC Networks
  • It has Moderate Oxidation Risk

Electric Wire Insulation Materials Temperature Ratings

Insulation TypeShort-Circuit Temp.Max. Operating Temp.
Silicone350 °C180 °C
XLPE250 °C90 °C
PVC160 °C70 °C
EPR250 °C90 °C
LSOH / LSZH160- 250 °C70-90 °C
Mica-Glass-250 °C continuous

Offer Cut to Size Industrial Power Cables in Low, Medium, High and Ultra High Voltage As Per Standards in Dammam

Electric Power Cable Voltage Classification

Saudi Arabia's Aramco and SEC Grid Infrastructure Uses All Four Voltage Bands. in KSA Projects Selecting the Wrong Voltage-Rated Cable is the Most Common Mistake

In Saudi Arabia Projects Below Power Cable Voltage Bands Used
Low Tension (LT) - 0.6/1 kVResidential & Commercial Wiring
25% usage
Medium Voltage (MV) - 3.8/6.6 kV to 19/33 kVIndustrial & Utility Distribution
50% usage
High Voltage (HV) - 35 kV to 220 kVTransmission & Substation Links
18% usage
Ultra High Voltage (UHV) - 220 kV & aboveBackbone Transmission Grid
7% usage

AYY/YY Power Cable Grades & Core

AYY/YY Designation Indicates Aluminium Conductor, PVC Insulated, PVC Sheathed LT Power Cables

StandardCable DesignationVoltage GradeConductorCore
IEC 60502-1AYY/YY - 3.5 Core Industrial Power Cable0.6/1 kVAluminium Stranded3½C
IEC 60502-1AYY/YY - 3 Core Multi Core Power Cable0.6/1 kVAluminium Stranded3C
IEC 60502-1AYY/YY - 1 Core LT Power Cable0.6/1 kVAluminium Stranded1C
IEC 60502-1AYY/YY - 4 Core Shielded Power Cable0.6/1 kVAluminium Stranded4C

Industrial Power Cable International Standards & SASO Compliance

StandardCable
IEC 60502-2MV Cables 1 to 30 kV
IEC 60502-1up to 1 kV LT Power Cables
BS 6346Armoured PVC Cables
BS 5467Armoured XLPE Cables
SASO IEC 60502 in Saudi Framework Adopted IEC
IEC 60754Halogen Content Test
IEC 60332Flame Retardancy Test
SASO 2406 LT Cables Saudi Standard

Need Power Cable Prices for Your KSA Project? Get Multiple Quotes Today

Send Your Specifications Include Voltage Grade, Core Count, Conductor Size, Insulation Type, and Required Drum Length On Contact@pipingmaterial.sa and Gete Multiple Quotes From Power Cable Suppliers in Saudi Arabia Within Hours.

Request Free Quote

How to Select the Right Electric Cable for Your Project?

Power Cable Selection in Saudi Arabia Must Account For Ambient Temperature (Outdoors +50 °C ), Installation Environment and SEC Approval Requirements.

Voltage Level
Deside Operating Voltage: LT (1 kV), MV (6.6-33 kV), or HV (above 33 kV)
Current Capacity
Calculate load current & apply KSA derating factor for 50 °C ambient temperature
Installation Method
cable tray → unarmoured XLPE; Direct burial → SWA armoured; conduit → flexible PVC
Environment
indoor plant → FR or LSZH; Outdoor KSA desert → UV-resistant sheath; oil-prone → EPR
Standard & Approval
IEC 60502, Confirm SASO, SEC spec Saudi Aramco Materials System compliance

AYY/YY-2 Core Power Cables Electrical Parameters

Cross Sectional Area Nominal at 70°C Maximum AC Conductor Resistance (Ω/km) at 20°C Maximum DC Conductor Resistance (Ω/km)Cables Approx. Capacitance (microF/KM)Approx. Reactanceat 50 Hz (Ω/km)Current Rating Of Short Circuit for 1sec. Duration(K.Amps)Cables Approx. Net Weight (Kg/Km)
CUALCUALAL Cond. CU Cond.
CUALGroundAirDuctGroundAirDuct
45.53-4.61-0.230.0980.460.304343028443937
63.75.533.084.610.280.0960.690.456434037555047
102.23.71.833.080.340.0911.150.76575348746761
161.382.291.151.910.400.0851.841.22787061948578
250.871.440.7271.20.420.0832.881.9959980120125100
350.631.040.5240.8680.480.0824.032.6611611794145155120
700.3220.5320.2680.4430.560.0768.055.32170176140210235175
500.4640.7690.3870.6410.490.0825.753.8140140110170190145
950.2320.3840.1930.320.580.07610.907.22200221165250290210
1500.14880.2470.1240.2060.630.07417.3011.4255294210315375270
1200.1840.3040.1530.2530.630.07513.809.12225258185285330240
2400.09120.1510.07540.1250.670.07327.618.2325402270410510350
1850.11890.1970.09910.1640.640.07421.2814.1285339235355435300
3000.07330.1220.06010.10.680.07334.522.8370461305460590390
5000.04590.07590.03660.06050.700.07257.538481624405580750480
4000.0580.09610.0470.07780.700.07246.030.4435542350520670440
6300.03680.0610.02830.04690.700.07272.5547.9537723470680875575

Construction Details Of Heavy Duty Electrical Wire

For Saudi Arabia's Harsh Climate Understanding Each Concentric Layer Of A Heavy Duty Cable Enables To Specify the Correct Product While Avoiding Under Specification

Outer PVC/LSZH Sheath SWA Armouring Bedding Layer Inner Sheath XLPE Insulation Cu/Al Conductor
Outer Sheath - PVC / LSZH / HDPE
Armouring - SWA / AWA / DSTA
Bedding / Fillers - PVC or LSOH Compound
Inner Sheath - PVC Binding Layer
XLPE / PVC Insulation
Copper / Aluminium Conductor

Industrial Power Cable Rating Factors

Multi Core Power Cables
Multicorelaying Depth in cmupto 25mm225mm2 and 300mm2 Above 300mm2 Above
0.099900.0990.0980.097
175111
0.0971200.0970.0960.095
0.095180 or more0.0950.0930.091
0.0981050.0980.0970.096
0.0961500.0960.0940.092

 

Single Core Power Cables
Nominal Area Conductor mm2Factor Rating
Including 185 and Upto1.007
3001.008
2401.010
5001.000
4001.004
6301.000
Find SASO Compliant Shielded Power Cable Online Most Suitable For Petrochemical Plant, Refer Shielded vs Unshielded
⚡

When to Use Shielded Power Cable vs Unshielded?

Comparison

Pick The Right Industrial Power Cable Based On EMI Protection, Voltage Rating, Safety, Cost and Your Project Environment in Saudi Arabia

Feature
Shielded Cable
Unshielded Cable
EMI Protection
✓ Metallic Screen
✘ No Screening
Voltage Range
MV : 3.8 kV & above
LT:0.6 / 1 kV
Installation
VFD Panels Variable-speed drives, instrumentation areas
General LT Lighting, socket-outlets, general feeders
Touch Safety
✓ Earthed Screen
○ Standard
Cost
screening layer
simpler build
Saudi Application
Aramco / SABIC Process plants, VFD pumps, clean rooms
Buildings Warehouses, residential complexes, building wiring

Technical Dimensions Of AYY/YY-1 Core LT Power Cables

Minimum Number of Strands in Conductor Cross Sectional Area NominalNominal Thickness of Insulation in mmApprox.Overall Dia. in mmNominal Thickness Of Outer Sheath in mmApprox. Net Weight Of Cable (Kg/Km)
ALCUCables AYY ALCables YY CU
66251.02131.08210365
66161.00111.08160260
53536303.04432.0427506650
66501.04161.08300610
1212701.04171.08400830
66351.02141.08250460
1515951.06191.085001100
535310003.04522.06410010300
15181501.08232.007501680
30301852.00252.009002050
15181201.06212.006001350
30342402.02282.0011002600
53534002.06352.0217004200
30343002.04302.0013503200
53535003.00382.0221505250
53538003.04482.0433008250

Industrial Applications Of High Heat Electrical Wire

  • Petrochemical Plant Power Distribution
  • Saudi Electricity Company MV Feeders
  • NEOM Gigaproject Backbone Cabling
  • Desalination Plant Electrical Systems
  • Industrial Power Cable for Steel Mills & Mining
  • Data Centre Critical Power Infrastructure
  • Solar Farm DC & AC Collection Cables
  • Hospital & Airport Emergency Power Wiring
  • Red Sea Project & AMAALA Resort Infrastructure
  • VFD-Driven Pump Station Power Cables
  • High-Rise Commercial Building Sub-Main Feeders
  • Auxiliary Power Cables and Metro Rail Traction

 

High Heat Industrial Power Cable Weight Per Meter

Values Applicable At 40 °c Ambient, 90 °c Conductor Temperature. Apply Saudi Derating Factor For 50 °c Ambient Outdoor Installations.

3.3/3.3 KV (UE) & 1.9/3.3 KV (E) As Per IS 7098-2 Three Core Copper Conductor XLPE Insulated Armoured & Unarmoured Cable
Nominal size of conductor sq.mmNominal insulation thickness mmUNARMOURED CABLEMinimum inner sheath thickness mmSTRIP ARMOURED CABLEWIRE ARMOURED CABLE
Approx. overall diameter mmNominal thickness of PVC outer sheath mmApprox. Cable Weight kg/mmMinimum PVC outer sheath thickness mmApprox. Cable Weight kg/mmNominal dimension of strip mmApprox. overall diameter mmNominal dimension of wire mmApprox. overall diameter mmMinimum PVC outer sheath thicknesApprox. Cable Weight kg/km
352.2352.220990.401.5625174 x 0.8362.0381.723079
252.2332.217260.401.5621054 x 0.8342.0361.562608
502.2382.225490.401.7230134 x 0.8382.0411.723599
952.2462.643470.501.8848784 x 0.8472.5502.045995
702.2422.433510.501.7238354 x 0.8422.0451.884511
3002.2673.4114380.702.52121524 x 0.8673.15722.6814456
1502.2532.862150.602.0468064 x 0.8532.5572.208111
1202.2502.652050.502.0458114 x 0.8502.5532.046961
2402.2623.294040.602.36100804 x 0.8623.15672.5212199
1852.2573.074650.602.2080794 x 0.8572.5612.369499
4002.2743.6142750.702.68150644 x 0.8743.15782.8417632

 

Medium Voltage Power Cable Demand in Saudi Arabia Market As Per Industrial Sector?

Saudi Arabia's Vision 2030 Made KSA Fastest-Growing Power Cable Markets in The Middle East. This Chart Shows Where Saudi Buyers Source Industrial Power Cables Most.

Saudi Power Cable Procurement by End-Use Sector (2024-2025 Demand Share)
KSA Cable Demand
32%  Oil, Gas & Petrochemical
25%  Building & Construction
18%  Power Utility & SEC Grid Distribution
14%  Industrial Manufacturing & Mining
11%  Renewables :Solar, Wind & Storage

AYY/YY-4 Core Shielded Power Cable Dimensions

Cross Sectional Area NominalMin. Number of Strands in ConductorApprox. Overall Dia. in mmMin. Inner Sheath Thickness in mmInsulation Nominal Thickness in mmOuter Sheath Nominal Thickness in mmCables Approx. Net Weight (kg/km)
CUALCables AYY AL Cables YY CU
61/71180.03 mm1.00 mm1.08380530
41/7-160.03 mm1.00 mm1.08290390
1061200.03 mm1.00 mm1.08530770
2566260.03 mm1.02 mm2.007401350
1666230.03 mm1.00 mm2.00550940
3566300.03 mm1.02 mm2.009251785
701212380.04 mm1.04 mm2.0215403285
5066340.04 mm1.04 mm2.0212302480
951515430.04 mm1.06 mm2.0420304385
1501815510.05 mm1.08 mm2.0629256650
1201815460.05 mm1.06 mm2.0423855360
1853030550.06 mm2.00 mm2.0836308230
3003430660.072.04 mm3.04548012950
5005353820.073.00 mm4.00858020980
2403430600.062.02 mm3.00458010530
4005353730.072.06 mm3.06678016700
6305353920.073.04 mm4.001098025980

List Of Solar Energy Power Cables

  • PV DC Solar Cable - 1.5 kV
  • AC Collection Cable - 0.6/1 kV XLPE
  • MV Export Cable - 33 kV
  • Wind Turbine Torsional Flexible Cable
  • Battery Energy Storage Cables
  • HVDC Submarine & Land Cable
  • UV-Resistant HDPE Sheathed Cables
  • Sand-Resistant Armoured Direct-Burial Cables
  • 70 °C Ambient Derated XLPE Cables

 

What are Fire Resistant Power Cables and Their Standards?

Cable TypeFire Standard
Flame Retardant Low SmokeIEC 60332-3
Flame RetardantIEC 60332-1
Fire Resistant LSZHIEC 60331 + IEC 60332
LSZH / LSOHIEC 60332-3 + IEC 60754
Mineral InsulatedBS EN 60702

What are the Safety Considerations Before Using Power Cable ?

  • Adequate insulation thickness
  • Correct current rating selection
  • Mechanical protection in harsh environments
  • Proper grounding and bonding

Ready to Source Power Cable for Your Saudi Arabia Project?

Submit Your Power Cable Specification like Voltage Class, Conductor Size, Cores, Armouring, Insulation, Standard (IEC/BS/SASO) With Delivery Location In KSA, Our Sourcing Team Will Connect You With Power Cable Suppliers in Saudi Arabia Who Keep Ex-stock Within the Same Day.

Get Free Quote Now

Approved Manufacturers Of Industrial Power Cable

  • Nexans: France / Norway
  • Prysmian Group: Italy
  • LS Cable & System: South Korea
  • Belden Inc.: USA
  • Saudi Cable Company: Jeddah, Saudi Arabia
  • Riyadh Cables Group: Riyadh, Saudi Arabia
  • National Pipe Company :Dammam, KSA
  • Bahra Cables: Jeddah, KSA
  • Finolex Cables: India
  • Polycab Wires: India
  • Draka / Prysmian: Netherlands
  • Hengtong Group:China

 

Dimensions Of AYY/YY-3 CORE Multi Core Power Cables

Nominal Cross Sectional Area(Sq. mm)Max. AC Conductor Resistance at70°C (Ω/km)Max. DC Conductor Resistance at20°C (Ω/km)Approx.Capacitance of Cables (microF/KM)Approx. Reactanceat 50 Hz(Ω/km)Normal Current Rating (Amps)Short Circuit Current Ratingfor 1sec. Duration(K.Amps)
GroundWith CU Cond.
CUALCUALGroundAirDuctGroundAirDuctCUAL
45.53-4.61-0.230.0982823233630300.460.304
63.75.533.084.610.280.0963530304539380.690.456
102.23.71.833.080.340.0914640396052501.150.76
161.382.291.151.910.40.0856051507766641.841.22
250.871.440.7271.20.420.0837670639990812.881.9
350.631.040.5240.8680.480.082928677120110994.032.66
500.4640.7690.3870.6410.490.082110105951451351255.753.8
700.3220.5320.2680.4430.560.0761351301151751651508.055.32
950.2320.3840.1930.320.580.07616515514021020017510.97.22
1200.1840.3040.1530.2530.630.07518518015524023019513.89.12
5000.04590.07590.03660.06050.70.07237042532047052039057.538
1500.14880.2470.1240.2060.630.07421020517527026522517.311.4
1850.11890.1970.09910.1640.640.07423524020030030525521.314.1
3000.07330.1220.06010.10.680.07330531526038540033534.522.8
6300.03680.0610.02830.04690.70.07240548035055567547072.547.9
2400.09120.1510.07540.1250.670.07327528023534535529527.618.2
4000.0580.09610.0470.07780.70.0723353752904254353604630.4

Power Cable Supplied to KSA Project Sites via Pipingmaterial.sa

Petrochemical & Refinery
6.6 kV, 3C×185 mm² Cu XLPE SWA - MV Feeder Cable
SABIC Jubail Petrochemical Complex
Jubail Industrial City, KSA
Power Generation
4C×300 mm² Al XLPE AWA - 0.6/1 kV LT Feeder
ACWA Power Rabigh-3 Plant
Rabigh, Saudi Arabia
Renewable Energy
DC PV Cable 1.5 kV, 1C×240 mm² - Solar Farm Strings
ACWA Sudair Solar Farm (1.5 GW)
Al-Sudair, Riyadh Region
Metro & Rail Infrastructure
FRLSZH 1C×120 mm² Cu XLPE - Traction Auxiliary Cable
Riyadh Metro Line 3 Extension
Riyadh, Saudi Arabia
Commercial Construction
AYY/YY 4C×95 mm² Al - Sub-Main Feeder Cables
NEOM Sindalah Island Resort Project
NEOM, Tabuk Region, KSA
Water & Desalination
3.5C×150 mm² Cu XLPE SWA - Pump Station MCC Feeder
SWPC Yanbu 4 Desalination Plant
Yanbu Al-Sinaiyah, KSA

Get Dealers and Distributors of Power Cable in Saudi Arabia

  • Al-Yusr Industrial Supplies, Riyadh
  • Zahid Tractor & Heavy Machinery, Jeddah
  • Rezayat Trading Company Ltd., Riyadh
  • Algosaibi Services Company, Al-Khobar
  • Binzagr International Trading, Dammam
  • Pan Gulf Industrial Holdings, Al-Khobar

Ready to Order Power Cable? Email Your Complete Specifications

Your Cable Need and Our Verified Network. Share Your Industrial Power Cable Requirements With contact@pipingmaterial.sa and We Will Match You Immediately With Verified Power Cable Suppliers in Saudi Arabia Who Holding the Material Ex-stock.

Get Free Quote
Disocver German and Turkey Origin High Heat Electrical Wire Ex. Stock With Complete Documentationand IEC/BS Test Report

Which Documentation Required When Importing Power Cable Into Saudi Arabia ?

  • Factory Test Certificate As per IEC 60502
  • ILAC-Accredited Type Test Report
  • SASO Certificate of Conformity
  • Drum Length & Construction Report
  • Country of Origin Certificate
  • IEC 60332 Flame Retardancy Test Report

Frequently Asked Questions

What is the Difference Between a Power Cable and an Electrical Wire?
An electric wire is a single conductor used for low-current inside panel. An electric power cable is a multi-layer assembly of one or more insulated conductors produce to carry high current safely
Which Voltage Grade Of Power Cable is Most Demanded Saudi Arabia?
Medium voltage (MV) cables in the 6.6 kV to 33 kV range is highest-demand in Saudi Arabia
Does Saudi Arabia Require SASO Approval For Imported Power Cables?
Yes. They Require SASO Certificate for all power cables imported into Saudi Arabia. The relevant standard is SASO IEC 60502
What Does AYY/YY Mean in Power Cable Designation?
A = Aluminium conductor; Y = PVC insulation (first Y = core insulation); Y = PVC outer sheath (second Y = outer jacket).
Why is Cable Current Capacity Derated in Saudi Arabia?
IEC standard current capacity tables are calculated assuming a 30 °C or 40 °C ambient temperature
What Certifications Do Saudi Aramco Power Cable Specifications Require?
Required certifications include IEC 60502 factory test reports, ILAC-accredited third-party type test reports, SASO CoC, SAMS vendor approval, flame propagation test per IEC 60332
⚡ FAST RESPONSE Get Quote in 2 Hours We respond quickly
📧 Your Email 📱 Your WhatsApp No. 🔍 What are you looking for?— choose how to reach you —
Get Quote in 2 Hrs ‹
⚡ FAST RESPONSE Get Quote in 2 Hours We respond quickly
📧 Your Email 📱 Your WhatsApp No. 🔍 What are you looking for?— choose how to reach you —