- Standards: IEC 60502, BS 5467, BS 6346, IEC 60227
- Cable Types: Single Core, Multi Core, Armoured, Unarmoured
- Conductor: Copper & Aluminium
- Insulation: XLPE, PVC, EPR, LSOH
- Voltage Range: 0.6/1 kV up to 33 kV
- Core Range: 1 Core to 5 Core
- Sizes Available: 1.5 mm² to 1000 mm²
- Sheathing: PVC Inner/Outer, HDPE, LSZH
- Armouring: SWA, AWA, DSTA, STA
- Test Reports: ILAC-Accredited Labs, IECEE
- HSN Code: 8544
- Origin: India, Turkey, China, Germany, Saudi Arabia

Get Verified Power Cable Suppliers in Saudi Arabia
Buy SEC Approved Single and Multi Core Electrical Wire Stock At Factory Price, Refer Armouring Types
pipingmaterial.sa Connects You Across Saudi Arabia Directly With Genuine Power Cable Stockists In Riyadh, Dammam, Jubail, And Jeddah. We Entirely Eliminate Middlemen and Connect You With Multiple Competitive Offers Carrying Full IEC-Compliant Documentation, Guaranteed Delivery Schedules, and Zero Commission On Our End. From Single Core Cables to AYY/YY Multi Core Shielded Power Cables, Every Product Meets SASO And IEC 60502 Need, Send Your Complete Specification To contact@pipingmaterial.sa Right Now
- Heavy Duty Power Cable Armouring Types
- Power Cable Specifications
- Power Cable Types As Per Construction
- Design Parameters Of AYY/YY-2 Core Power Cables
- Copper vs Aluminium Conductor Materials
- Electric Wire Insulation Materials Temperature Ratings
- Electric Power Cable Voltage Classification
- AYY/YY Power Cable Grades & Core
- Industrial Power Cable International Standards & SASO Compliance
- How to Select the Right Electric Cable for Your Project?
- AYY/YY-2 Core Power Cables Electrical Parameters
- Construction Details Of Heavy Duty Electrical Wire
- Industrial Power Cable Rating Factors
- When to Use Shielded Power Cable vs Unshielded?
- Technical Dimensions Of AYY/YY-1 Core LT Power Cables
- Industrial Applications Of High Heat Electrical Wire
- High Heat Industrial Power Cable Weight Per Meter
- Medium Voltage Power Cable Demand in Saudi Arabia Market As Per Industrial Sector?
- AYY/YY-4 Core Shielded Power Cable Dimensions
- List Of Solar Energy Power Cables
- What are Fire Resistant Power Cables and Their Standards?
- What are the Safety Considerations Before Using Power Cable ?
- Approved Manufacturers Of Industrial Power Cable
- Dimensions Of AYY/YY-3 CORE Multi Core Power Cables
- Which Documentation Required When Importing Power Cable Into Saudi Arabia ?
- Frequently Asked Questions
Heavy Duty Power Cable Armouring Types
Power Cable Specifications
Your Single Inquiry On Pipingmaterial.sa Connects You With Multiple Verified Power Cable Stockists in Saudi Arabia Without Middlemen At Real Prices.
- 1.5 to 1000 mm²
- Copper & Aluminium
- Solid or Stranded
- Class 1, 2, 5 & 6
- LT: 0.6/1 kV
- MV: 3.8/6.6 kV to 8.7/15 kV
- MV: 12.7/22 kV to 19/33 kV
- HV: 64/110 kV & above
- Single Core
- 2 Core & 3 Core
- 3.5 Core & 4 Core
- 5 Core Multi Core
- XLPE
- PVC
- EPR
- LSOH / LSZH
- SWA: Steel Wire Armour
- AWA: Aluminium Wire
- DSTA: Double Steel Tape
- STA: Single Tape Armour
- PVC ST1 / ST2
- HDPE
- LSZH / LSOH
- Flame-Retardant
- IEC 60502-1 & -2
- BS 5467 / BS 6346
- IEC 60332 Flame Test
- IEC 60754 Halogen Free
- Factory Test Certificate
- Drum Length Report
- ILAC Lab Test Report
- SASO Conformity Cert.
- Non-returnable Wooden Drum
- 100 m, 200 m, 500 m Rolls
- Cut-to-length on Order
- Custom Drumming Available
Power Cable Types As Per Construction
Power Cable Stockists in Saudi Arabia On Our Platform Maintain Ready Inventory Across All Core Configurations, Voltage Grades, and Armour Types








Other Cables in Ex-Stock
| Cross Sectional Area Nominal | Conductor Min. Number of Strands | Approx. Overall Dia(mm) | Inner Sheath Min Thickness in mm | Insulation Nominal Thickness in mm | Outer Sheath Nominal Thickness in mm | Approx. Net Weight Of Cables (Kg/Km) | ||
|---|---|---|---|---|---|---|---|---|
| CU | AL | Cables YY CU | Cables AYY AL | |||||
| 6 | 1/7 | 1 | 17 | 0.03 | 1.00 | 1.08 | 370 | 300 |
| 4 | 1/7 | - | 14 | 0.03 | 1.00 | 1.08 | 290 | 240 |
| 10 | 6 | 1 | 18 | 0.03 | 1.00 | 1.08 | 520 | 400 |
| 25 | 6 | 6 | 19 | 0.03 | 1.02 | 2.00 | 750 | 450 |
| 16 | 6 | 6 | 17 | 0.03 | 1.00 | 1.08 | 630 | 430 |
| 35 | 6 | 6 | 21 | 0.03 | 1.02 | 2.00 | 980 | 550 |
| 70 | 12 | 12 | 26 | 0.03 | 1.04 | 2.00 | 1700 | 850 |
| 50 | 6 | 6 | 24 | 0.03 | 1.04 | 2.00 | 1300 | 700 |
| 95 | 15 | 15 | 30 | 0.04 | 1.06 | 2.02 | 2300 | 1150 |
| 150 | 18 | 15 | 34 | 0.04 | 1.08 | 2.04 | 3450 | 1600 |
| 120 | 18 | 15 | 32 | 0.04 | 1.06 | 2.02 | 2800 | 1300 |
| 185 | 30 | 30 | 38 | 0.05 | 2.00 | 2.04 | 4300 | 2000 |
| 500 | 53 | 53 | 54 | 0.07 | 3.00 | 3.04 | 11000 | 4800 |
| 300 | 34 | 30 | 46 | 0.06 | 2.04 | 2.08 | 6700 | 3000 |
| 240 | 34 | 30 | 42 | 0.05 | 2.02 | 2.06 | 5500 | 2500 |
| 400 | 53 | 53 | 52 | 0.07 | 2.06 | 3.02 | 8750 | 3800 |
| 630 | 53 | 53 | 65 | 0.07 | 3.04 | 3.08 | 13800 | 6000 |
Get Copper and Aluminium Conductor Heavy Duty Power Cable Stockists in Riyadh With Various Insulation
Copper Conductor Cable
- Electrical Conductivity is 58 MS/m
- It has Excellent Flexibility Cl. 5 & 6
- Use in LT, Industrial, Control.Shielded
- Saudi Market Prefer For LT Installations & Panel Wiring
- It has Low Oxidation Risk
Aluminium Conductor Cable
- Electrical Conductivity is 35 MS/m
- It has Good Flexibility Cl. 1 & 2
- Use in Overhead Feeders, MV/HV Distribution
- Its Prefer in MV Grid Cables & SEC Networks
- It has Moderate Oxidation Risk
Electric Wire Insulation Materials Temperature Ratings
| Insulation Type | Short-Circuit Temp. | Max. Operating Temp. |
|---|---|---|
| Silicone | 350 °C | 180 °C |
| XLPE | 250 °C | 90 °C |
| PVC | 160 °C | 70 °C |
| EPR | 250 °C | 90 °C |
| LSOH / LSZH | 160- 250 °C | 70-90 °C |
| Mica-Glass | - | 250 °C continuous |
Offer Cut to Size Industrial Power Cables in Low, Medium, High and Ultra High Voltage As Per Standards in Dammam
Electric Power Cable Voltage Classification
Saudi Arabia's Aramco and SEC Grid Infrastructure Uses All Four Voltage Bands. in KSA Projects Selecting the Wrong Voltage-Rated Cable is the Most Common Mistake
AYY/YY Power Cable Grades & Core
AYY/YY Designation Indicates Aluminium Conductor, PVC Insulated, PVC Sheathed LT Power Cables
| Standard | Cable Designation | Voltage Grade | Conductor | Core |
|---|---|---|---|---|
| IEC 60502-1 | AYY/YY - 3.5 Core Industrial Power Cable | 0.6/1 kV | Aluminium Stranded | 3½C |
| IEC 60502-1 | AYY/YY - 3 Core Multi Core Power Cable | 0.6/1 kV | Aluminium Stranded | 3C |
| IEC 60502-1 | AYY/YY - 1 Core LT Power Cable | 0.6/1 kV | Aluminium Stranded | 1C |
| IEC 60502-1 | AYY/YY - 4 Core Shielded Power Cable | 0.6/1 kV | Aluminium Stranded | 4C |
Industrial Power Cable International Standards & SASO Compliance
| Standard | Cable |
|---|---|
| IEC 60502-2 | MV Cables 1 to 30 kV |
| IEC 60502-1 | up to 1 kV LT Power Cables |
| BS 6346 | Armoured PVC Cables |
| BS 5467 | Armoured XLPE Cables |
| SASO IEC 60502 | in Saudi Framework Adopted IEC |
| IEC 60754 | Halogen Content Test |
| IEC 60332 | Flame Retardancy Test |
| SASO 2406 | LT Cables Saudi Standard |
Need Power Cable Prices for Your KSA Project? Get Multiple Quotes Today
Send Your Specifications Include Voltage Grade, Core Count, Conductor Size, Insulation Type, and Required Drum Length On Contact@pipingmaterial.sa and Gete Multiple Quotes From Power Cable Suppliers in Saudi Arabia Within Hours.
Request Free QuoteHow to Select the Right Electric Cable for Your Project?
Power Cable Selection in Saudi Arabia Must Account For Ambient Temperature (Outdoors +50 °C ), Installation Environment and SEC Approval Requirements.
| Cross Sectional Area Nominal | at 70°C Maximum AC Conductor Resistance (Ω/km) | at 20°C Maximum DC Conductor Resistance (Ω/km) | Cables Approx. Capacitance (microF/KM) | Approx. Reactanceat 50 Hz (Ω/km) | Current Rating Of Short Circuit for 1sec. Duration(K.Amps) | Cables Approx. Net Weight (Kg/Km) | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CU | AL | CU | AL | AL Cond. | CU Cond. | |||||||||
| CU | AL | Ground | Air | Duct | Ground | Air | Duct | |||||||
| 4 | 5.53 | - | 4.61 | - | 0.23 | 0.098 | 0.46 | 0.304 | 34 | 30 | 28 | 44 | 39 | 37 |
| 6 | 3.7 | 5.53 | 3.08 | 4.61 | 0.28 | 0.096 | 0.69 | 0.456 | 43 | 40 | 37 | 55 | 50 | 47 |
| 10 | 2.2 | 3.7 | 1.83 | 3.08 | 0.34 | 0.091 | 1.15 | 0.76 | 57 | 53 | 48 | 74 | 67 | 61 |
| 16 | 1.38 | 2.29 | 1.15 | 1.91 | 0.40 | 0.085 | 1.84 | 1.22 | 78 | 70 | 61 | 94 | 85 | 78 |
| 25 | 0.87 | 1.44 | 0.727 | 1.2 | 0.42 | 0.083 | 2.88 | 1.9 | 95 | 99 | 80 | 120 | 125 | 100 |
| 35 | 0.63 | 1.04 | 0.524 | 0.868 | 0.48 | 0.082 | 4.03 | 2.66 | 116 | 117 | 94 | 145 | 155 | 120 |
| 70 | 0.322 | 0.532 | 0.268 | 0.443 | 0.56 | 0.076 | 8.05 | 5.32 | 170 | 176 | 140 | 210 | 235 | 175 |
| 50 | 0.464 | 0.769 | 0.387 | 0.641 | 0.49 | 0.082 | 5.75 | 3.8 | 140 | 140 | 110 | 170 | 190 | 145 |
| 95 | 0.232 | 0.384 | 0.193 | 0.32 | 0.58 | 0.076 | 10.90 | 7.22 | 200 | 221 | 165 | 250 | 290 | 210 |
| 150 | 0.1488 | 0.247 | 0.124 | 0.206 | 0.63 | 0.074 | 17.30 | 11.4 | 255 | 294 | 210 | 315 | 375 | 270 |
| 120 | 0.184 | 0.304 | 0.153 | 0.253 | 0.63 | 0.075 | 13.80 | 9.12 | 225 | 258 | 185 | 285 | 330 | 240 |
| 240 | 0.0912 | 0.151 | 0.0754 | 0.125 | 0.67 | 0.073 | 27.6 | 18.2 | 325 | 402 | 270 | 410 | 510 | 350 |
| 185 | 0.1189 | 0.197 | 0.0991 | 0.164 | 0.64 | 0.074 | 21.28 | 14.1 | 285 | 339 | 235 | 355 | 435 | 300 |
| 300 | 0.0733 | 0.122 | 0.0601 | 0.1 | 0.68 | 0.073 | 34.5 | 22.8 | 370 | 461 | 305 | 460 | 590 | 390 |
| 500 | 0.0459 | 0.0759 | 0.0366 | 0.0605 | 0.70 | 0.072 | 57.5 | 38 | 481 | 624 | 405 | 580 | 750 | 480 |
| 400 | 0.058 | 0.0961 | 0.047 | 0.0778 | 0.70 | 0.072 | 46.0 | 30.4 | 435 | 542 | 350 | 520 | 670 | 440 |
| 630 | 0.0368 | 0.061 | 0.0283 | 0.0469 | 0.70 | 0.072 | 72.55 | 47.9 | 537 | 723 | 470 | 680 | 875 | 575 |
Construction Details Of Heavy Duty Electrical Wire
For Saudi Arabia's Harsh Climate Understanding Each Concentric Layer Of A Heavy Duty Cable Enables To Specify the Correct Product While Avoiding Under Specification
| Multi Core Power Cables | ||||
|---|---|---|---|---|
| Multicore | laying Depth in cm | upto 25mm2 | 25mm2 and 300mm2 Above | 300mm2 Above |
| 0.099 | 90 | 0.099 | 0.098 | 0.097 |
| 1 | 75 | 1 | 1 | 1 |
| 0.097 | 120 | 0.097 | 0.096 | 0.095 |
| 0.095 | 180 or more | 0.095 | 0.093 | 0.091 |
| 0.098 | 105 | 0.098 | 0.097 | 0.096 |
| 0.096 | 150 | 0.096 | 0.094 | 0.092 |
| Single Core Power Cables | |
|---|---|
| Nominal Area Conductor mm2 | Factor Rating |
| Including 185 and Upto | 1.007 |
| 300 | 1.008 |
| 240 | 1.010 |
| 500 | 1.000 |
| 400 | 1.004 |
| 630 | 1.000 |
Find SASO Compliant Shielded Power Cable Online Most Suitable For Petrochemical Plant, Refer Shielded vs Unshielded
Pick The Right Industrial Power Cable Based On EMI Protection, Voltage Rating, Safety, Cost and Your Project Environment in Saudi Arabia
| Minimum Number of Strands in Conductor | Cross Sectional Area Nominal | Nominal Thickness of Insulation in mm | Approx.Overall Dia. in mm | Nominal Thickness Of Outer Sheath in mm | Approx. Net Weight Of Cable (Kg/Km) | ||
|---|---|---|---|---|---|---|---|
| AL | CU | Cables AYY AL | Cables YY CU | ||||
| 6 | 6 | 25 | 1.02 | 13 | 1.08 | 210 | 365 |
| 6 | 6 | 16 | 1.00 | 11 | 1.08 | 160 | 260 |
| 53 | 53 | 630 | 3.04 | 43 | 2.04 | 2750 | 6650 |
| 6 | 6 | 50 | 1.04 | 16 | 1.08 | 300 | 610 |
| 12 | 12 | 70 | 1.04 | 17 | 1.08 | 400 | 830 |
| 6 | 6 | 35 | 1.02 | 14 | 1.08 | 250 | 460 |
| 15 | 15 | 95 | 1.06 | 19 | 1.08 | 500 | 1100 |
| 53 | 53 | 1000 | 3.04 | 52 | 2.06 | 4100 | 10300 |
| 15 | 18 | 150 | 1.08 | 23 | 2.00 | 750 | 1680 |
| 30 | 30 | 185 | 2.00 | 25 | 2.00 | 900 | 2050 |
| 15 | 18 | 120 | 1.06 | 21 | 2.00 | 600 | 1350 |
| 30 | 34 | 240 | 2.02 | 28 | 2.00 | 1100 | 2600 |
| 53 | 53 | 400 | 2.06 | 35 | 2.02 | 1700 | 4200 |
| 30 | 34 | 300 | 2.04 | 30 | 2.00 | 1350 | 3200 |
| 53 | 53 | 500 | 3.00 | 38 | 2.02 | 2150 | 5250 |
| 53 | 53 | 800 | 3.04 | 48 | 2.04 | 3300 | 8250 |
Industrial Applications Of High Heat Electrical Wire
- Petrochemical Plant Power Distribution
- Saudi Electricity Company MV Feeders
- NEOM Gigaproject Backbone Cabling
- Desalination Plant Electrical Systems
- Industrial Power Cable for Steel Mills & Mining
- Data Centre Critical Power Infrastructure
- Solar Farm DC & AC Collection Cables
- Hospital & Airport Emergency Power Wiring
- Red Sea Project & AMAALA Resort Infrastructure
- VFD-Driven Pump Station Power Cables
- High-Rise Commercial Building Sub-Main Feeders
- Auxiliary Power Cables and Metro Rail Traction
High Heat Industrial Power Cable Weight Per Meter
Values Applicable At 40 °c Ambient, 90 °c Conductor Temperature. Apply Saudi Derating Factor For 50 °c Ambient Outdoor Installations.
| 3.3/3.3 KV (UE) & 1.9/3.3 KV (E) As Per IS 7098-2 Three Core Copper Conductor XLPE Insulated Armoured & Unarmoured Cable | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Nominal size of conductor sq.mm | Nominal insulation thickness mm | UNARMOURED CABLE | Minimum inner sheath thickness mm | STRIP ARMOURED CABLE | WIRE ARMOURED CABLE | |||||||||
| Approx. overall diameter mm | Nominal thickness of PVC outer sheath mm | Approx. Cable Weight kg/mm | Minimum PVC outer sheath thickness mm | Approx. Cable Weight kg/mm | Nominal dimension of strip mm | Approx. overall diameter mm | Nominal dimension of wire mm | Approx. overall diameter mm | Minimum PVC outer sheath thicknes | Approx. Cable Weight kg/km | ||||
| 35 | 2.2 | 35 | 2.2 | 2099 | 0.40 | 1.56 | 2517 | 4 x 0.8 | 36 | 2.0 | 38 | 1.72 | 3079 | |
| 25 | 2.2 | 33 | 2.2 | 1726 | 0.40 | 1.56 | 2105 | 4 x 0.8 | 34 | 2.0 | 36 | 1.56 | 2608 | |
| 50 | 2.2 | 38 | 2.2 | 2549 | 0.40 | 1.72 | 3013 | 4 x 0.8 | 38 | 2.0 | 41 | 1.72 | 3599 | |
| 95 | 2.2 | 46 | 2.6 | 4347 | 0.50 | 1.88 | 4878 | 4 x 0.8 | 47 | 2.5 | 50 | 2.04 | 5995 | |
| 70 | 2.2 | 42 | 2.4 | 3351 | 0.50 | 1.72 | 3835 | 4 x 0.8 | 42 | 2.0 | 45 | 1.88 | 4511 | |
| 300 | 2.2 | 67 | 3.4 | 11438 | 0.70 | 2.52 | 12152 | 4 x 0.8 | 67 | 3.15 | 72 | 2.68 | 14456 | |
| 150 | 2.2 | 53 | 2.8 | 6215 | 0.60 | 2.04 | 6806 | 4 x 0.8 | 53 | 2.5 | 57 | 2.20 | 8111 | |
| 120 | 2.2 | 50 | 2.6 | 5205 | 0.50 | 2.04 | 5811 | 4 x 0.8 | 50 | 2.5 | 53 | 2.04 | 6961 | |
| 240 | 2.2 | 62 | 3.2 | 9404 | 0.60 | 2.36 | 10080 | 4 x 0.8 | 62 | 3.15 | 67 | 2.52 | 12199 | |
| 185 | 2.2 | 57 | 3.0 | 7465 | 0.60 | 2.20 | 8079 | 4 x 0.8 | 57 | 2.5 | 61 | 2.36 | 9499 | |
| 400 | 2.2 | 74 | 3.6 | 14275 | 0.70 | 2.68 | 15064 | 4 x 0.8 | 74 | 3.15 | 78 | 2.84 | 17632 | |
Medium Voltage Power Cable Demand in Saudi Arabia Market As Per Industrial Sector?
Saudi Arabia's Vision 2030 Made KSA Fastest-Growing Power Cable Markets in The Middle East. This Chart Shows Where Saudi Buyers Source Industrial Power Cables Most.
| Cross Sectional Area Nominal | Min. Number of Strands in Conductor | Approx. Overall Dia. in mm | Min. Inner Sheath Thickness in mm | Insulation Nominal Thickness in mm | Outer Sheath Nominal Thickness in mm | Cables Approx. Net Weight (kg/km) | ||
|---|---|---|---|---|---|---|---|---|
| CU | AL | Cables AYY AL | Cables YY CU | |||||
| 6 | 1/7 | 1 | 18 | 0.03 mm | 1.00 mm | 1.08 | 380 | 530 |
| 4 | 1/7 | - | 16 | 0.03 mm | 1.00 mm | 1.08 | 290 | 390 |
| 10 | 6 | 1 | 20 | 0.03 mm | 1.00 mm | 1.08 | 530 | 770 |
| 25 | 6 | 6 | 26 | 0.03 mm | 1.02 mm | 2.00 | 740 | 1350 |
| 16 | 6 | 6 | 23 | 0.03 mm | 1.00 mm | 2.00 | 550 | 940 |
| 35 | 6 | 6 | 30 | 0.03 mm | 1.02 mm | 2.00 | 925 | 1785 |
| 70 | 12 | 12 | 38 | 0.04 mm | 1.04 mm | 2.02 | 1540 | 3285 |
| 50 | 6 | 6 | 34 | 0.04 mm | 1.04 mm | 2.02 | 1230 | 2480 |
| 95 | 15 | 15 | 43 | 0.04 mm | 1.06 mm | 2.04 | 2030 | 4385 |
| 150 | 18 | 15 | 51 | 0.05 mm | 1.08 mm | 2.06 | 2925 | 6650 |
| 120 | 18 | 15 | 46 | 0.05 mm | 1.06 mm | 2.04 | 2385 | 5360 |
| 185 | 30 | 30 | 55 | 0.06 mm | 2.00 mm | 2.08 | 3630 | 8230 |
| 300 | 34 | 30 | 66 | 0.07 | 2.04 mm | 3.04 | 5480 | 12950 |
| 500 | 53 | 53 | 82 | 0.07 | 3.00 mm | 4.00 | 8580 | 20980 |
| 240 | 34 | 30 | 60 | 0.06 | 2.02 mm | 3.00 | 4580 | 10530 |
| 400 | 53 | 53 | 73 | 0.07 | 2.06 mm | 3.06 | 6780 | 16700 |
| 630 | 53 | 53 | 92 | 0.07 | 3.04 mm | 4.00 | 10980 | 25980 |
List Of Solar Energy Power Cables
- PV DC Solar Cable - 1.5 kV
- AC Collection Cable - 0.6/1 kV XLPE
- MV Export Cable - 33 kV
- Wind Turbine Torsional Flexible Cable
- Battery Energy Storage Cables
- HVDC Submarine & Land Cable
- UV-Resistant HDPE Sheathed Cables
- Sand-Resistant Armoured Direct-Burial Cables
- 70 °C Ambient Derated XLPE Cables
What are Fire Resistant Power Cables and Their Standards?
| Cable Type | Fire Standard |
|---|---|
| Flame Retardant Low Smoke | IEC 60332-3 |
| Flame Retardant | IEC 60332-1 |
| Fire Resistant LSZH | IEC 60331 + IEC 60332 |
| LSZH / LSOH | IEC 60332-3 + IEC 60754 |
| Mineral Insulated | BS EN 60702 |
What are the Safety Considerations Before Using Power Cable ?
- Adequate insulation thickness
- Correct current rating selection
- Mechanical protection in harsh environments
- Proper grounding and bonding
Ready to Source Power Cable for Your Saudi Arabia Project?
Submit Your Power Cable Specification like Voltage Class, Conductor Size, Cores, Armouring, Insulation, Standard (IEC/BS/SASO) With Delivery Location In KSA, Our Sourcing Team Will Connect You With Power Cable Suppliers in Saudi Arabia Who Keep Ex-stock Within the Same Day.
Get Free Quote NowApproved Manufacturers Of Industrial Power Cable
- Nexans: France / Norway
- Prysmian Group: Italy
- LS Cable & System: South Korea
- Belden Inc.: USA
- Saudi Cable Company: Jeddah, Saudi Arabia
- Riyadh Cables Group: Riyadh, Saudi Arabia
- National Pipe Company :Dammam, KSA
- Bahra Cables: Jeddah, KSA
- Finolex Cables: India
- Polycab Wires: India
- Draka / Prysmian: Netherlands
- Hengtong Group:China
| Nominal Cross Sectional Area(Sq. mm) | Max. AC Conductor Resistance at70°C (Ω/km) | Max. DC Conductor Resistance at20°C (Ω/km) | Approx.Capacitance of Cables (microF/KM) | Approx. Reactanceat 50 Hz(Ω/km) | Normal Current Rating (Amps) | Short Circuit Current Ratingfor 1sec. Duration(K.Amps) | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Ground | With CU Cond. | |||||||||||||
| CU | AL | CU | AL | Ground | Air | Duct | Ground | Air | Duct | CU | AL | |||
| 4 | 5.53 | - | 4.61 | - | 0.23 | 0.098 | 28 | 23 | 23 | 36 | 30 | 30 | 0.46 | 0.304 |
| 6 | 3.7 | 5.53 | 3.08 | 4.61 | 0.28 | 0.096 | 35 | 30 | 30 | 45 | 39 | 38 | 0.69 | 0.456 |
| 10 | 2.2 | 3.7 | 1.83 | 3.08 | 0.34 | 0.091 | 46 | 40 | 39 | 60 | 52 | 50 | 1.15 | 0.76 |
| 16 | 1.38 | 2.29 | 1.15 | 1.91 | 0.4 | 0.085 | 60 | 51 | 50 | 77 | 66 | 64 | 1.84 | 1.22 |
| 25 | 0.87 | 1.44 | 0.727 | 1.2 | 0.42 | 0.083 | 76 | 70 | 63 | 99 | 90 | 81 | 2.88 | 1.9 |
| 35 | 0.63 | 1.04 | 0.524 | 0.868 | 0.48 | 0.082 | 92 | 86 | 77 | 120 | 110 | 99 | 4.03 | 2.66 |
| 50 | 0.464 | 0.769 | 0.387 | 0.641 | 0.49 | 0.082 | 110 | 105 | 95 | 145 | 135 | 125 | 5.75 | 3.8 |
| 70 | 0.322 | 0.532 | 0.268 | 0.443 | 0.56 | 0.076 | 135 | 130 | 115 | 175 | 165 | 150 | 8.05 | 5.32 |
| 95 | 0.232 | 0.384 | 0.193 | 0.32 | 0.58 | 0.076 | 165 | 155 | 140 | 210 | 200 | 175 | 10.9 | 7.22 |
| 120 | 0.184 | 0.304 | 0.153 | 0.253 | 0.63 | 0.075 | 185 | 180 | 155 | 240 | 230 | 195 | 13.8 | 9.12 |
| 500 | 0.0459 | 0.0759 | 0.0366 | 0.0605 | 0.7 | 0.072 | 370 | 425 | 320 | 470 | 520 | 390 | 57.5 | 38 |
| 150 | 0.1488 | 0.247 | 0.124 | 0.206 | 0.63 | 0.074 | 210 | 205 | 175 | 270 | 265 | 225 | 17.3 | 11.4 |
| 185 | 0.1189 | 0.197 | 0.0991 | 0.164 | 0.64 | 0.074 | 235 | 240 | 200 | 300 | 305 | 255 | 21.3 | 14.1 |
| 300 | 0.0733 | 0.122 | 0.0601 | 0.1 | 0.68 | 0.073 | 305 | 315 | 260 | 385 | 400 | 335 | 34.5 | 22.8 |
| 630 | 0.0368 | 0.061 | 0.0283 | 0.0469 | 0.7 | 0.072 | 405 | 480 | 350 | 555 | 675 | 470 | 72.5 | 47.9 |
| 240 | 0.0912 | 0.151 | 0.0754 | 0.125 | 0.67 | 0.073 | 275 | 280 | 235 | 345 | 355 | 295 | 27.6 | 18.2 |
| 400 | 0.058 | 0.0961 | 0.047 | 0.0778 | 0.7 | 0.072 | 335 | 375 | 290 | 425 | 435 | 360 | 46 | 30.4 |
Power Cable Supplied to KSA Project Sites via Pipingmaterial.sa
Get Dealers and Distributors of Power Cable in Saudi Arabia
- Al-Yusr Industrial Supplies, Riyadh
- Zahid Tractor & Heavy Machinery, Jeddah
- Rezayat Trading Company Ltd., Riyadh
- Algosaibi Services Company, Al-Khobar
- Binzagr International Trading, Dammam
- Pan Gulf Industrial Holdings, Al-Khobar
Ready to Order Power Cable? Email Your Complete Specifications
Your Cable Need and Our Verified Network. Share Your Industrial Power Cable Requirements With contact@pipingmaterial.sa and We Will Match You Immediately With Verified Power Cable Suppliers in Saudi Arabia Who Holding the Material Ex-stock.
Get Free QuoteDisocver German and Turkey Origin High Heat Electrical Wire Ex. Stock With Complete Documentationand IEC/BS Test Report
- Factory Test Certificate As per IEC 60502
- ILAC-Accredited Type Test Report
- SASO Certificate of Conformity
- Drum Length & Construction Report
- Country of Origin Certificate
- IEC 60332 Flame Retardancy Test Report
Frequently Asked Questions