Looking for Trailing Rubber Cable in Saudi Arabia? Here's Why Buyers Choose pipingmaterial.sa
EPR & CSP Rubber Cables In Stock
Flexible Trailing Rubber Cables Ready for Crane & Mining Applications
Best Price on Rubber Cable Quotes
Multiple Trailing Cable Suppliers Quoted Instantly for KSA Projects
IEC & IS Certified Cable Suppliers
Trailing Cables From Verified IEC 60245 Compliant Manufacturers
Full Test Certificate Package
Routine Tests • Type Tests • IEC 60245 • TPI Available
Ex-Stock at Saudi Locations
Jubail • Dammam • Riyadh • Jeddah
High-Flex EPR Insulated Supply
241.1 Grade • 0.6/1kV to 3.8/6.6kV • Zero Middleman
Trailing Rubber Cable Snapshot
  • Cable Type: Trailing Rubber Cable
  • Standard: IEC 60245 / IS 9968 / BS 6708
  • Voltage Rating: 0.6/1kV, 1.9/3.3kV, 3.8/6.6kV
  • Conductor: Annealed Stranded Copper
  • Insulation: EPR/ HEPR
  • Inner Sheath: CSP / Rubber
  • Outer Sheath: Heavy-Duty Polychloroprene / CSP
  • Core Range: 2 Core to 48 Core
  • Cross Section: 1.5 mm² to 400 mm²
  • Cable Grade: 241.1, 241.2, 241.3
  • Operating Temp: -40°C to +90°C
  • Flexibility: Extra Flexible
  • MTC: Routine Test • Type Test Certificate • Third Party Inspection
  • Preferred Origin: India, Germany, South Korea, Turkey, UAE
Trailing Rubber Cable

Meet Genuine Trailing Rubber Cable Suppliers in Saudi Arabia

Get IEC 60245 Compliant EPR Insulated Cables Suppliers in Saudi Arabia, Refer Specification

pipingmaterial.sa Connects Buyers Directly With Verified Trailing Rubber Cable Stockists in Saudi Arabia Without Commission. With 25 Years Of Industry Experience, The Platform Lists IEC 60245, IS 9968 and BS 6708 Certified Trailing Copper Cable Manufacturers With Full Test Documents. Buyers Get Multiple Competitive Offers Instantly And EPR and Rubber Trailing Cables Ex-stock From Indian, European And Korean Trailing Rubber Cable Suppliers in Saudi Arabia Which Are Ready For Fast Delivery To Riyadh, Jubail, Jeddah and Dammam. pipingmaterial.sa is a free B2B platform that connects Saudi buyers directly to verified cable and material suppliers.Just send one inquiry about what you need. Our team finds suppliers who actually keep that stock in Saudi . You get quotes from 5-10 suppliers with delivery dates no middleman, no commission.26 years in industrial sourcing. We know the stockists. You get the best deal.

About This Guide

✎ Updated: June 16, 2026

Written by pipingmaterial.sa Expert Team: 26 years supplying trailing rubber cables to Saudi mining, industrial & mobile equipment operators

✓ 1000+ trailing cable installations for cranes, conveyors, drag chains & reeling equipment across KSA

✓ Verified supplier of heavy-duty trailing cables for oil & gas field operations in Aramco, SABIC facilities

✓ Free access - no login needed

✓ Direct supplier contact (email, phone, WhatsApp)

✓ Competing quotes with delivery estimates

✓ ADNOC approved & SABIC approved suppliers listed

✓ Save time & money

Aramco Approved SABIC Approved ADNOC Approved
Stock and Supply :
DammamAl Khobar Al Jubail Yanbu Jeddah Sudair Tabuk Riyadh Rabigh Ras Al-Khair Hafr Al-BatinDhahran
Provide :
IEC 60245 Certified IS 9968 Compliant BS 6708 Routine & Type Test Certificate Third Party Inspection EPR / CSP / PCP Cables

Complete Specification of EPR Insulated Trailing Cable

Pipingmaterial.sa Delivers Your Inquiry Directly to Multiple Genuine Trailing Rubber Cable Stockists in Saudi Arabia Simultaneously Without Delays and Middleman

Trailing Cable Manufacturing Origin
  • India
  • Germany & Turkey
  • South Korea
  • UAE
Trailing Cable Voltage Rating
  • 0.6/1kV
  • 1.9/3.3kV
  • 3.8/6.6kV
  • 6.35/11kV
Rubber Cable Construction
  • Class 5 / Class 6
  • EPR or HEPR
  • CSP
  • PCP / CSP
Trailing Cable Core Count
  • 2 Core to 5 Core
  • 6 Core to 12 Core
  • 14 Core to 30 Core
  • Up to 48 Core
Conductor Cross Section Range
  • 1.5 mm² to 10 mm²
  • 16 mm² to 95 mm²
  • 120 mm² to 240 mm²
  • 300 mm² to 400 mm²
Trailing Cable Testing Standards
  • Conductor Resistance Test
  • High Voltage Withstand Test
  • Insulation Resistance Test
  • Bend & Flexibility Cycle Test
Trailing Rubber Cable Drum Length
  • 100 Metre
  • 200 Metre & 500 Metre
  • Custom Cut Length Available
  • 500 Metre Max
Trailing Cable Mill Documents
  • IEC 60245 Routine Test Certificate
  • Type Test Certificate
  • Third Party Inspection Report
  • Heat Lot Traceability Record
Flexible Trailing Cable Grade
  • Extra Flexible Class 6 Conductor
  • Minimum Bending Radius: 6×OD
  • Torsion & Trailing Duty Rated
  • Oil & Ozone Resistant Sheath

Buy IS 9968 and BS 6708 Certified Trailing Copper Cable in Dammam For Cranes, Mining & High-Mast Applications

Why EPR Insulated Trailing Cable for Crane and Mining Projects ?

Overhead Crane Power Supply (EOT, Gantry, Portal)
Open-Cast Mining Excavators & Shovels
Flexible EPR Trailing Highmast Cables
Moving Conveyor Systems & Feeders
Harbour & Container Terminal Cranes
Outdoor Mobile Plant & Wind-Exposed Sites
Petrochemical Mobile Substations KSA
NEOM & Vision 2030 Construction Equipment
Trailing Cords for Welding Machines
Mobile Lighting Towers & Transformers
Substation Earthing Trailing Wires
Highway & Tunnel Construction Equipment

Types of Rubber Trailing Cables Available in Stock

Before ordering, match the cable grade to your voltage level and working conditions, Trailing cables come in different types, each designed for a specific voltage, duty and environment

Light Duty Trailing Cable
⚡

Light Duty Trailing Cable

  • Voltage: 0.6/1kV
  • Grade: IEC 60245 241.1
  • Sheath: PCP Outer
  • Use: Welding, small cranes
Crane Trailing Rubber Cable
🏗

Crane Trailing Rubber Cable

  • Voltage: 1.9/3.3kV
  • Grade: IEC 60245 241.2
  • Sheath: CSP + PCP Dual
  • Use: EOT & gantry cranes
Mining Grade Trailing Cable
⛏

Mining Grade Trailing Cable

  • Voltage: 3.8/6.6kV
  • Grade: IEC 60245 241.3
  • Sheath: Heavy CSP Outer
  • Use: Excavators, shovels
Flexible EPR Highmast Trailing
🌅

Flexible EPR Highmast Trailing

  • Voltage: 0.6/1kV to 3.3kV
  • UV & ozone resistant sheath
  • Class 6 ultra-fine stranding
  • Use: KSA highmast lighting
Composite Trailing Cable
🔗

Composite Trailing Cable

  • Power + control cores combined
  • Optional pilot & earth cores
  • EPR insulated all cores
  • Use: Cranes with control loops
Trailing Copper Cable
🔌

Trailing Copper Cable

  • Individual core copper screen
  • Overall copper braid shield
  • Low capacitance design
  • Use: VFD-driven crane motors

Need Trailing Rubber Cable Suppliers in Saudi Arabia? Get Matched Fast

Share your voltage rating, core count and drum length. We connect you with verified Trailing Rubber Cable Suppliers in Saudi Arabia without delay.

Request Stock Check

Get Genuine Trailing Rubber Cable Manufacturers Stock List

Trailing Rubber Cable Stockists in Saudi Arabia Who Carry the Material Will Respond On The Same Working Day When You Share Your Quantity, Core Count, Cross Section and Voltage Rating

Polycab
Polycab India
Finolex Cables
Finolex Cables
Havells India
Havells India
Lapp Kabel Germany
Lapp Kabel Germany
Belden
Belden USA
LS Cable Korea
LS Cable Korea
Bhuwal Insulation
Bhuwal Insulation
Platima Cable
Platima Cable
Oriental Cables
Oriental Cables
Nexans
Nexans France

Find German Origin Rubber Insulated Trailing Cable Stockists in Jubail Who Supply With Routine Test, Refer Current Rating Chart

Trailing Cable Current Rating Chart

Direct Access To Trailing Rubber Cable Suppliers in Saudi Arabia Who Hold Actual Inventory Without Involvement Of Traders and Third-party Padding

CONDUCTORINSULATION
NO.  & SIZE OF WIREAREADIAMETER
OF WIRE
DC OR SINGLE
PHASE AC
SEPARATE
IN AIR
MAX. 
RESISTANCE
AT 20°C
NOMINAL
OVERALL
DIAMETER
NOMINAL
THICKNESS
MMSQ.   MM. MMAMPS.OHM/KM.MMMM
24/.200.751.24625.002.550.6
16/.2O0.500.95437.502.300.6
32/.201.001.311018.702.700.6
80/.202.502.08207.983.650.7
48/.201.501.641513.002.950.6
128/.204.002.64254.954.350.8
140/. 3010.04.6641.887.151.0
85/. 306.003.2463.1245.650.8
101/.4516.05.9851.1408.951.4
220/.4535.08.71380.52511.751.4
168/.4525.07.61120.72110.651.4
325A4550.010.61720.36214.051.6
485/. 5095.014.72540.19518.751.9
440/.4570.012.32140.26116.151.8
614/. 50120.016.73000.15221.252.1
925/.50185.020.33900.10125.502.5
943A45150.018.33400.12522.502.2
1221/.50240.023.04600.07628.502.5

Supplied Trailing Rubber Cable for Cranes in Below Projects in Saudi Arabia

EOT Crane Power Supply
3-Core 95mm² 3.8/6.6kV EPR Trailing Cable with CSP Sheath
SABIC Ma'aden Aluminium Complex, Al Jubail
Al Jubail, Saudi Arabia
Highmast Lighting Flexible Trailing
Flexible EPR Trailing Highmast Cables 4-Core 16mm² 0.6/1kV UV Resistant
King Abdulaziz Road Highmast Lighting Project
Riyadh, Saudi Arabia
Port Container Crane Trailing
Composite 12-Core Trailing Rubber Cable 1.9/3.3kV with Pilot Cores
King Abdulaziz Port Expansion Phase 2
Dammam, Saudi Arabia
NEOM Construction Heavy Equipment
3-Core 240mm² 3.8/6.6kV Mining Grade Rubber Trailing Cable
NEOM THE LINE Infrastructure Programme
Tabuk, Saudi Arabia
Refinery Mobile Substation Cable
Flexible Trailing Electrical Cable 4-Core 50mm² 1.9/3.3kV Flame Retardant
Saudi Aramco Ras Tanura Refinery Upgrade
Ras Tanura, Saudi Arabia
Conveyor & Feeder Power Trailing
Rubber Trailing Cable 3.5-Core 185mm² 0.6/1kV Class 6 Flexible
Ma'aden Phosphate Plant Conveyor System
Yanbu, Saudi Arabia
Offer Flexible Rubber Trailing Wires Ex.Stock in Various Grades Of IEC 60245 like 241.1 / 241.2 / 241.3, See Comparison

IEC 60245 Grade 241.1 vs 241.2 vs 241.3

KSA Engineers Often Struggle To Pick The Right IEC 60245 Grade For Their Cable Order. Wrong Grade Means Early Wasted Cost On Light Duty Sites Or Sheath Failure In Heavy Duty, See Comparison To Choose Correct Grade

IEC 60245 Grade Guide
Property
241.1 - Light Duty
241.2 - Medium Duty
241.3 - Heavy Duty
Voltage
0.6/1 kV
1.9/3.3 kV
3.8/6.6 kV
Conductor
Class 5 Cu
Class 5/6 Cu
Class 6 Fine Cu
Insulation
EPR / Rubber
HEPR
HEPR / EPR
Sheath
PCP Standard
CSP + PCP
Heavy CSP
Max Temp
+75°C
+90°C
+90°C
Flame Ret.
Optional
Standard
Standard
Mining Use
Not Rated
Partial
Approved
KSA Use
Highmast, Welding
EOT Cranes, Ports
Mining, NEOM

Mechanical Properties of Trailing Rubber Cable

PropertyTest StandardEPR InsulationPCP Outer SheathCSP Inner Sheath
Elongation at BreakIEC 60811-1-1≥ 250%≥ 300%≥ 300%
Tensile StrengthIEC 60811-1-1≥ 6.0 N/mm²≥ 10.0 N/mm²≥ 8.0 N/mm²
Min Operating TempIEC 60245-40°C-40°C-40°C
Max Operating TempIEC 60245+90°C (EPR)+90°C+90°C
Volume ResistivityIEC 60093≥ 1 × 10¹² Ω·cm--
Short Circuit TempIEC 60724250°C (5 sec)--
Oil ResistanceIEC 60811-2-1GoodExcellentExcellent
HV WithstandIEC 60245 §26.5kV AC (1kV cable)--
Ozone ResistanceIEC 60811-2-1ExcellentExcellentExcellent
Flame RetardancyIEC 60332-1-IEC 60332-1IEC 60332-1
Bending Radius (fixed)IEC 602454 × Overall OD--
UV ResistanceIEC 60811-4-1GoodExcellentGood
Bending Radius (trailing)IEC 602456 × Overall OD--

CSP vs EPR Rubber Trailing Cable Sheaths As Per Chemical Resistance

Trailing Cables Face Oil, Chemicals, Fuel and Harsh UV Daily in KSA Petrochemical and Mining Sites. Choosing The Right Compound is Critical For Long Cable Life Because The Wrong Outer Sheath Will Fail Fast

🧪

Dilute Acids

  • EPR Very Good
  • CSP Very Good
  • PCP Good
Both suitable
🛡

Mineral Oils

  • EPR Good
  • CSP Excellent
  • PCP Very Good
CSP preferred
🌊

Marine

  • EPR Excellent
  • CSP Excellent
  • PCP Excellent
All suitable
🧼

Alkalis & Washdown

  • EPR Excellent
  • CSP Excellent
  • PCP Excellent
All suitable
🔥

Heat Exposure

  • EPR Good
  • CSP Excellent
  • PCP Very Good
CSP preferred
⚗

Aromatic Solvents

  • EPR Poor
  • CSP Good
  • PCP Fair
CSP only
☀

Ozone & UV

  • EPR Excellent
  • CSP Excellent
  • PCP Very Good
CSP preferred
🌫

Dust Abrasion

  • EPR –
  • CSP Very Good
  • PCP Excellent
PCP outer preferred
💧

Hot Water

  • EPR Very Good
  • CSP Good
  • PCP Very Good
EPR preferred

Trailing Cable Core Colour Code Chart

Older KSA Plants May Use BS 6708 On Legacy Crane Cables But IEC 60446 is Required by Saudi Aramco & SABIC.
2-Core
Single-phase trailing cord
IEC 60446
Brown Blue
BS 6708
Red Black
3-Core
3-phase flexible trailing wire
IEC 60446
Brown Black Grey
BS 6708
Red Yellow Blue
3.5-Core
3-phase + reduced neutral trailing cable
IEC 60446
Brown Black Grey Blue (reduced)
BS 6708
Red Yellow Blue Black (reduced)
4-Core
3-phase + neutral, 0.6/1kV trailing
IEC 60446
Brown Black Grey Blue
BS 6708
Red Yellow Blue Black
5-Core
3-phase + neutral + earth trailing
IEC 60446
Brown Black Grey Blue Green/Yellow
BS 6708
Red Yellow Blue Black Green/Yellow
Pilot Core
Control signal core in composite cables
IEC 60446
Orange / Numbered
BS 6708
White / Numbered
Earth Core
Protective earth in all trailing cables
IEC 60446
Green / Yellow Stripe
BS 6708
Green / Yellow Stripe

How Saudi Arabia Buyers Choose Trailing Cables in 2025?

When Purchasing Trailing Cables Saudi Arabia Buyers Follow Three Main Patterns: Highmast Lighting, Mining, and Port Cranes.
🌅
Highmast Lighting (Vision 2030)
Highways and stadiums in Riyadh, Jeddah and NEOM use flexible EPR trailing cables rated 0.6/1kV with UV-resistant sheath and IEC 60245 certification.
Riyadh · Jeddah · Tabuk
⚡
Ma'aden Mining Operations
Phosphate and aluminium mines use 3.8/6.6kV heavy-duty trailing cable with thick CSP sheath to handle rough rocky ground conditions.
Wa'ad Al Shamal · Yanbu
🏗
Port Crane Expansion
Dammam and Jeddah ports use composite trailing cable with power and pilot cores in one 1.9/3.3kV jacket, screened for VFD compatibility.
Dammam · Jeddah
🏭
Petrochemical Mobile Substations
Aramco and SABIC use flame-retardant EPR trailing cables rated 1.9/3.3kV with LSZH sheath for temporary connections during plant shutdowns.
Al Jubail · Ras Tanura

Need IEC Certified Trailing Cable with Test Certificates?

Tell us your IEC grade, cross-section and certificate requirements. Ex-stock EPR Trailing Rubber Cable ready for Riyadh, Jeddah, Jubail and Dammam.

Get Certified Quote
Discover Trailing Electrical Cables Online With Different Bending Radius and Voltage Rating

Trailing Rubber Electrical Cables Bending Radius

When Equipment Moves Trailing Rubber Cable Bend Every Time, Bending Too Tight Damages The Conductor Strands Over Time. To Avoid Wire Breaks And Insulation Cracks Always Follow The Minimum Bending Radius

H/05 to VDE 0282 300/500VWeight Approx Kg/1000mOuter DiamiterAmps Per CoreGland
Section mm225°C30°C
3 x 1,0877.817.8517  PG9
3 x 0,75757.314.714  PG9
4 x 1,51659.922.0521  PG9
3 x 1,51359.522.0521  PG9
4 x 2,523512.431.530  PG11
H/07 to VDE 0282 450/750VWeight Approx Kg/1000mOuter DiamiterAmps Per CoreGland
Section mm225°C30°C
1 x 5072018212202  PG21
1 x 3552016170162  PG21
1 x 7094021262250  PG29
1 x 120151025370353  PG29
1 x 95122023316301  PG29
1 x 150185028410391  PG29
3 x 4310154341  PG16
3 x 2,52351331.530  PG16
3 x 6400175553  PG21
3 x 1610002510499  PG29
3 x 10810227774  PG29
3 x 25147030137131  PG36
4 x 2,52801431.530  PG16
3 x 35195034170162  PG42
4 x 4380174341  PG21
4 x 10940247774  PG29
4 x 6510195553  PG21
4 x 1612502710499  PG29
4 x 35231036170162  PG42
4 x 25185032137131  PG36
4 x 50316041212202  PG48
5 x 2.53401523.622.5  PG16
4 x 70425046262250  PG48
5 x 44701833.330.75  PG21
7 x 2.54642020.519.5  PG29
7 x 1.53161714.313.65  PG16
7 x 46802327.9826.65  PG36
24 x 1.5980288.828.4  PG36
8 x 1.53501612.1311.55  PG29
7 x 68082636.1734.45  PG36
8 x 2.551019.220.519.5  PG29
12 x 2.57452417.3716.55  PG29
12 x 1.56002212.1311.55  PG29
19 x 2.512503014.1813.5  PG36
24 x 2.514803412.612  PG42

What Are The Reasons Of Trailing Cable Fail? Know How to Troubleshoot It ?

Cable Failures Cause Costly Delays. Spot The Problem Early And Fix It Quickly.
01
Conductor Fatigue Break

Strands snap at tight bend points.

02
Sheath Cracking (UV & Ozone)

Desert UV splits unprotected sheath.

03
Oil Swelling / Sheath Delamination

Hydraulic oil swells non-rated sheath.

04
Wrong Grade for Voltage Class

Wrong voltage rating breaks insulation.

05
Abrasion Through Outer Sheath

Dragging wears sheath, lets moisture in.

Trailing Rubber Cable Voltage Rating

When Buying Trailing Cable Choosing The Right Voltage Rating Is The Most Important Step . A Mismatched Cable On KSA's 380v Or 11kv Systems Creates Safety Risks and Voids The Warranty

Voltage Rating Cable RatingPhaseInsulation Thickness GradeSheath Recommended
380V / 415V0.6/1 kV3-Phase1.2-1.6 mm241.1 or 241.2PCP Standard
240V0.6/1 kVSingle Phase1.2-1.6 mm241.1PCP or CSP
6.6 kV3.8/6.6 kV3-Phase5.5 mm241.3Heavy CSP
3.3 kV1.9/3.3 kV3-Phase3.4 mm241.2CSP + PCP
11 kV6.35/11 kV3-Phase7.0 mmSpecial MiningHeavy CSP + Armour

Test Certificates Required When Buying Trailing Cables for Saudi Projects?

Saudi Aramco, SABIC and NEOM Require Specific Certificates Before Approving Any Trailing Rubber Cable Order. Knowing Which Documents are Needed Upfront Avoids Delays At Site Inspection.

  • Routine Test Certificate (RTC)
  • Type Test Certificate (TTC)
  • Third Party Inspection (TPI)
  • Flame Test Certificate
  • Halogen Content Certificate
  • Country of Origin Certificate
  • Drum Packing Specification
  • Heat & Lot Traceability Record

Trailing Rubber Cables Delivery Lead Time to Dammam

Ex-Stock KSA: 3-7 Working Days
Sea Freight India Origin: 10-14 Weeks
Air Freight Partial: 5-8 Working Days
Custom Build Europe: 14-18 Weeks
Minimum Order: 1 Full Drum
TPI Witnessing: Add 5-7 Working Days

Trailing Copper Cable vs Aluminium Conductor

Why Copper is Always Specified
  • Without Fracturing Flexes
  • Lighter Drum Because Of Smaller Diameter
  • Standard Lugs, Easy Termination
  • Approved Under IEC 60245
Why Aluminium Gets Rejected
  • Cracks On Reel Drum Cycles
  • Salt-air Corrodes Joints Fast
  • Larger Cross-section, No Weight Gain
  • Not on Aramco Approved List

Find Trailing Rubber Cable Dealers and Distributors in Saudi Arabia

  • Saudi Cable Company, Jeddah
  • Al-Babtain Power & Telecom, Dammam
  • Tamimi Markets & Industrial Supplies, Riyadh
  • National Electrical Industries, Al Jubail
  • Al Othman Trading & Contracting, Dammam
  • Riyadh Cables Group, Riyadh
  • Gulf Cable & Electrical Industries, Kuwait (KSA stock)
  • Arabian Electrical Industries, Jeddah
  • Al-Khobar Electrical Materials, Al Khobar

Related Flexible Rubber Cable Available in Ex.Stock

🔌

Flexible Welding Cables

  • 16 mm² to 95 mm²
  • Fine stranded copper
  • Rubber insulated
  • IEC 60245-6
⚙

Festoon Flat Trailing Cable

  • 2 to 24 cores
  • Flat profile for festoon systems
  • PVC or PCP sheath
  • Crane overhead systems
🌡

Heat Resistant Silicone Cable

  • Up to +180°C rating
  • Silicone rubber insulation
  • Fine wire Cu conductor
  • Furnace & oven trailing
🛡

Armoured Rubber Cable

  • SWA or SWB armour
  • EPR insulated cores
  • Mining & outdoor use
  • IEC 60502 / BS 6708
📡

Composite Control Trailing

  • Power + control + pilot
  • Individual core screens
  • EPR insulated all cores
  • PCP / CSP dual sheath
💧

Submersible Pump Trailing

  • Waterproof construction
  • EPR insulated 3-core
  • 0.6/1kV rating
  • Dewatering pump systems

Trailing Wires Temperature Rating

60°C Thermoplastic or Thermosetting Insulated Cords:
Correction Factor:0.910.820.710.580.41
Ambient Temperature:35°C40°C45°C50°C55°C
90°C Thermoplastic or Thermosetting Insulated Cords:
Correction Factor:1.00.960.830.670.47
Ambient Temperature:35°C to 50°C55°C60°C65°C70°C
180°C Thermosetting Insulated Cords:
Correction Factor:1.00.960.850.740.600.42
Ambient Temperature:35°C to 120°C125°C130°C135°C140°C145°C
Glass Fibre Cords:
Correction Factor:1.00.920.820.710.510.40
Ambient Temperature:35°C to 150°C155°C160°C165°C170°C175°C

Trailing Cable Storage & Drum Handling

🌡
Storage Temperature
Store between 0°C and 45°C. Avoid direct sun exposure on drums outdoors in KSA heat.
Max 45°C
⛭
Drum Orientation
Always store drums upright on their flanges. Never lay flat - this deforms the cable under drum weight.
Upright Only
↻
Uncoiling Direction
Unreel from the top of the drum, never pull from a coil lying flat - causes twist and kinking.
Top Feed
⚙
Handling on Site
Use a drum stand or jack. Never drop drums or roll over rough ground without lagging protection.
Drum Stand Required

Send Your Trailing Rubber Cable Specifications via Email and Get Quotes Today

Email Your Trailing Cable Specs Like Size, Cores, Voltage, Quantity And Certificate To contact@pipingmaterial.sa. We Will Instantly Match You With Verified Trailing Rubber Cable Stockists in Saudi Arabia Who Have Your Exact Requirement Ready.

Get Free Quote

Flexible Rubber Trailing Wire Weight

conductor Cross-sectionmm24 × 954 × 70
mm² per conductor and cores numberOD in mmWeight in kg/kmCopper Weight in kg/km
4 G 2.512.1 - 15.523596
3 G 2.510.9 - 1418572
7 G 2.517.1 - 21.8520168
5 G 2.513.3 - 17290120
4 G 6.015.7 - 20440230.4
5 G 4.015.6 - 19.9410192
4 G 50.037.7 - 47.528101920
4 G 16mm23.8 - 30.11070614.4
5 G 6.017.5 - 22.2550288
4 G 25.028.9 - 36.61570960

How to Select Trailing Cords for Industrial Equipment ?

Step 1 VOLTAGE
Check Supply
0.6/1kV · 3.3kV · 6.6kV
Rule
Cable voltage must meet or exceed motor supply voltage
Step 3 SHEATH
Site Condition
UV · Oil · Abrasion
Rule
CSP for oil; UV-stabilised PCP for outdoor KSA highmast
⚡ FAST RESPONSE Get Quote in 2 Hours We respond quickly
📧 Your Email 📱 Your WhatsApp No. 🔍 What are you looking for?— choose how to reach you —
Get Quote in 2 Hrs ‹
⚡ FAST RESPONSE Get Quote in 2 Hours We respond quickly
📧 Your Email 📱 Your WhatsApp No. 🔍 What are you looking for?— choose how to reach you —