- Cable Type: Trailing Rubber Cable
- Standard: IEC 60245 / IS 9968 / BS 6708
- Voltage Rating: 0.6/1kV, 1.9/3.3kV, 3.8/6.6kV
- Conductor: Annealed Stranded Copper
- Insulation: EPR/ HEPR
- Inner Sheath: CSP / Rubber
- Outer Sheath: Heavy-Duty Polychloroprene / CSP
- Core Range: 2 Core to 48 Core
- Cross Section: 1.5 mm² to 400 mm²
- Cable Grade: 241.1, 241.2, 241.3
- Operating Temp: -40°C to +90°C
- Flexibility: Extra Flexible
- MTC: Routine Test • Type Test Certificate • Third Party Inspection
- Preferred Origin: India, Germany, South Korea, Turkey, UAE

Meet Genuine Trailing Rubber Cable Suppliers in Saudi Arabia
Get IEC 60245 Compliant EPR Insulated Cables Suppliers in Saudi Arabia, Refer Specification
pipingmaterial.sa Connects Buyers Directly With Verified Trailing Rubber Cable Stockists in Saudi Arabia Without Commission. With 25 Years Of Industry Experience, The Platform Lists IEC 60245, IS 9968 and BS 6708 Certified Trailing Copper Cable Manufacturers With Full Test Documents. Buyers Get Multiple Competitive Offers Instantly And EPR and Rubber Trailing Cables Ex-stock From Indian, European And Korean Trailing Rubber Cable Suppliers in Saudi Arabia Which Are Ready For Fast Delivery To Riyadh, Jubail, Jeddah and Dammam. pipingmaterial.sa is a free B2B platform that connects Saudi buyers directly to verified cable and material suppliers.Just send one inquiry about what you need. Our team finds suppliers who actually keep that stock in Saudi . You get quotes from 5-10 suppliers with delivery dates no middleman, no commission.26 years in industrial sourcing. We know the stockists. You get the best deal.
About This Guide
Written by pipingmaterial.sa Expert Team: 26 years supplying trailing rubber cables to Saudi mining, industrial & mobile equipment operators
✓ 1000+ trailing cable installations for cranes, conveyors, drag chains & reeling equipment across KSA
✓ Verified supplier of heavy-duty trailing cables for oil & gas field operations in Aramco, SABIC facilities
✓ Free access - no login needed
✓ Direct supplier contact (email, phone, WhatsApp)
✓ Competing quotes with delivery estimates
✓ ADNOC approved & SABIC approved suppliers listed
✓ Save time & money
![]()
- Complete Specification of EPR Insulated Trailing Cable
- Why EPR Insulated Trailing Cable for Crane and Mining Projects ?
- Types of Rubber Trailing Cables Available in Stock
- Get Genuine Trailing Rubber Cable Manufacturers Stock List
- Trailing Cable Current Rating Chart
- Supplied Trailing Rubber Cable for Cranes in Below Projects in Saudi Arabia
- IEC 60245 Grade 241.1 vs 241.2 vs 241.3
- Mechanical Properties of Trailing Rubber Cable
- CSP Vs EPR Rubber Trailing Cable Sheaths As Per Chemical Resistance
- Trailing Cable Core Colour Code Chart
- How Saudi Arabia Buyers Choose Trailing Cables in 2025?
- Trailing Rubber Electrical Cables Bending Radius
- Reasons Of Trailing Cable Fail? Know How to Troubleshoot It ?
- Trailing Rubber Cable Voltage Rating
- Test Certificates Required When Buying Trailing Cables for Saudi Projects?
- Trailing Rubber Cables Delivery Lead Time to Dammam
- Trailing Copper Cable vs Aluminium Conductor ?
- Related Flexible Rubber Cable Available in Ex.Stock
- Trailing Wires Temperature Rating
- Trailing Cable Storage & Drum Handling
- Flexible Rubber Trailing Wire Weight
- How to Select Trailing Cords for Industrial Equipment
Pipingmaterial.sa Delivers Your Inquiry Directly to Multiple Genuine Trailing Rubber Cable Stockists in Saudi Arabia Simultaneously Without Delays and Middleman
- India
- Germany & Turkey
- South Korea
- UAE
- 0.6/1kV
- 1.9/3.3kV
- 3.8/6.6kV
- 6.35/11kV
- Class 5 / Class 6
- EPR or HEPR
- CSP
- PCP / CSP
- 2 Core to 5 Core
- 6 Core to 12 Core
- 14 Core to 30 Core
- Up to 48 Core
- 1.5 mm² to 10 mm²
- 16 mm² to 95 mm²
- 120 mm² to 240 mm²
- 300 mm² to 400 mm²
- Conductor Resistance Test
- High Voltage Withstand Test
- Insulation Resistance Test
- Bend & Flexibility Cycle Test
- 100 Metre
- 200 Metre & 500 Metre
- Custom Cut Length Available
- 500 Metre Max
- IEC 60245 Routine Test Certificate
- Type Test Certificate
- Third Party Inspection Report
- Heat Lot Traceability Record
- Extra Flexible Class 6 Conductor
- Minimum Bending Radius: 6×OD
- Torsion & Trailing Duty Rated
- Oil & Ozone Resistant Sheath
Buy IS 9968 and BS 6708 Certified Trailing Copper Cable in Dammam For Cranes, Mining & High-Mast Applications
Why EPR Insulated Trailing Cable for Crane and Mining Projects ?
Types of Rubber Trailing Cables Available in Stock
Before ordering, match the cable grade to your voltage level and working conditions, Trailing cables come in different types, each designed for a specific voltage, duty and environment

Light Duty Trailing Cable
- Voltage: 0.6/1kV
- Grade: IEC 60245 241.1
- Sheath: PCP Outer
- Use: Welding, small cranes

Crane Trailing Rubber Cable
- Voltage: 1.9/3.3kV
- Grade: IEC 60245 241.2
- Sheath: CSP + PCP Dual
- Use: EOT & gantry cranes

Mining Grade Trailing Cable
- Voltage: 3.8/6.6kV
- Grade: IEC 60245 241.3
- Sheath: Heavy CSP Outer
- Use: Excavators, shovels

Flexible EPR Highmast Trailing
- Voltage: 0.6/1kV to 3.3kV
- UV & ozone resistant sheath
- Class 6 ultra-fine stranding
- Use: KSA highmast lighting

Composite Trailing Cable
- Power + control cores combined
- Optional pilot & earth cores
- EPR insulated all cores
- Use: Cranes with control loops

Trailing Copper Cable
- Individual core copper screen
- Overall copper braid shield
- Low capacitance design
- Use: VFD-driven crane motors
Need Trailing Rubber Cable Suppliers in Saudi Arabia? Get Matched Fast
Share your voltage rating, core count and drum length. We connect you with verified Trailing Rubber Cable Suppliers in Saudi Arabia without delay.
Request Stock CheckGet Genuine Trailing Rubber Cable Manufacturers Stock List
Trailing Rubber Cable Stockists in Saudi Arabia Who Carry the Material Will Respond On The Same Working Day When You Share Your Quantity, Core Count, Cross Section and Voltage Rating










Find German Origin Rubber Insulated Trailing Cable Stockists in Jubail Who Supply With Routine Test, Refer Current Rating Chart
Trailing Cable Current Rating Chart
Direct Access To Trailing Rubber Cable Suppliers in Saudi Arabia Who Hold Actual Inventory Without Involvement Of Traders and Third-party Padding
| CONDUCTOR | INSULATION | ||||||
|---|---|---|---|---|---|---|---|
| NO. & SIZE OF WIRE | AREA | DIAMETER OF WIRE | DC OR SINGLE PHASE AC SEPARATE IN AIR | MAX. RESISTANCE AT 20°C | NOMINAL OVERALL DIAMETER | NOMINAL THICKNESS | |
| MM | SQ. MM. | MM | AMPS. | OHM/KM. | MM | MM | |
| 24/.20 | 0.75 | 1.24 | 6 | 25.00 | 2.55 | 0.6 | |
| 16/.2O | 0.50 | 0.95 | 4 | 37.50 | 2.30 | 0.6 | |
| 32/.20 | 1.00 | 1.31 | 10 | 18.70 | 2.70 | 0.6 | |
| 80/.20 | 2.50 | 2.08 | 20 | 7.98 | 3.65 | 0.7 | |
| 48/.20 | 1.50 | 1.64 | 15 | 13.00 | 2.95 | 0.6 | |
| 128/.20 | 4.00 | 2.64 | 25 | 4.95 | 4.35 | 0.8 | |
| 140/. 30 | 10.0 | 4.6 | 64 | 1.88 | 7.15 | 1.0 | |
| 85/. 30 | 6.00 | 3.2 | 46 | 3.124 | 5.65 | 0.8 | |
| 101/.45 | 16.0 | 5.9 | 85 | 1.140 | 8.95 | 1.4 | |
| 220/.45 | 35.0 | 8.7 | 138 | 0.525 | 11.75 | 1.4 | |
| 168/.45 | 25.0 | 7.6 | 112 | 0.721 | 10.65 | 1.4 | |
| 325A45 | 50.0 | 10.6 | 172 | 0.362 | 14.05 | 1.6 | |
| 485/. 50 | 95.0 | 14.7 | 254 | 0.195 | 18.75 | 1.9 | |
| 440/.45 | 70.0 | 12.3 | 214 | 0.261 | 16.15 | 1.8 | |
| 614/. 50 | 120.0 | 16.7 | 300 | 0.152 | 21.25 | 2.1 | |
| 925/.50 | 185.0 | 20.3 | 390 | 0.101 | 25.50 | 2.5 | |
| 943A45 | 150.0 | 18.3 | 340 | 0.125 | 22.50 | 2.2 | |
| 1221/.50 | 240.0 | 23.0 | 460 | 0.076 | 28.50 | 2.5 | |
Supplied Trailing Rubber Cable for Cranes in Below Projects in Saudi Arabia
Offer Flexible Rubber Trailing Wires Ex.Stock in Various Grades Of IEC 60245 like 241.1 / 241.2 / 241.3, See Comparison
IEC 60245 Grade 241.1 vs 241.2 vs 241.3
KSA Engineers Often Struggle To Pick The Right IEC 60245 Grade For Their Cable Order. Wrong Grade Means Early Wasted Cost On Light Duty Sites Or Sheath Failure In Heavy Duty, See Comparison To Choose Correct Grade
Mechanical Properties of Trailing Rubber Cable
| Property | Test Standard | EPR Insulation | PCP Outer Sheath | CSP Inner Sheath |
|---|---|---|---|---|
| Elongation at Break | IEC 60811-1-1 | ≥ 250% | ≥ 300% | ≥ 300% |
| Tensile Strength | IEC 60811-1-1 | ≥ 6.0 N/mm² | ≥ 10.0 N/mm² | ≥ 8.0 N/mm² |
| Min Operating Temp | IEC 60245 | -40°C | -40°C | -40°C |
| Max Operating Temp | IEC 60245 | +90°C (EPR) | +90°C | +90°C |
| Volume Resistivity | IEC 60093 | ≥ 1 × 10¹² Ω·cm | - | - |
| Short Circuit Temp | IEC 60724 | 250°C (5 sec) | - | - |
| Oil Resistance | IEC 60811-2-1 | Good | Excellent | Excellent |
| HV Withstand | IEC 60245 §2 | 6.5kV AC (1kV cable) | - | - |
| Ozone Resistance | IEC 60811-2-1 | Excellent | Excellent | Excellent |
| Flame Retardancy | IEC 60332-1 | - | IEC 60332-1 | IEC 60332-1 |
| Bending Radius (fixed) | IEC 60245 | 4 × Overall OD | - | - |
| UV Resistance | IEC 60811-4-1 | Good | Excellent | Good |
| Bending Radius (trailing) | IEC 60245 | 6 × Overall OD | - | - |
CSP vs EPR Rubber Trailing Cable Sheaths As Per Chemical Resistance
Trailing Cables Face Oil, Chemicals, Fuel and Harsh UV Daily in KSA Petrochemical and Mining Sites. Choosing The Right Compound is Critical For Long Cable Life Because The Wrong Outer Sheath Will Fail Fast
Dilute Acids
- EPR Very Good
- CSP Very Good
- PCP Good
Mineral Oils
- EPR Good
- CSP Excellent
- PCP Very Good
Marine
- EPR Excellent
- CSP Excellent
- PCP Excellent
Alkalis & Washdown
- EPR Excellent
- CSP Excellent
- PCP Excellent
Heat Exposure
- EPR Good
- CSP Excellent
- PCP Very Good
Aromatic Solvents
- EPR Poor
- CSP Good
- PCP Fair
Ozone & UV
- EPR Excellent
- CSP Excellent
- PCP Very Good
Dust Abrasion
- EPR –
- CSP Very Good
- PCP Excellent
Hot Water
- EPR Very Good
- CSP Good
- PCP Very Good
Trailing Cable Core Colour Code Chart
How Saudi Arabia Buyers Choose Trailing Cables in 2025?
Need IEC Certified Trailing Cable with Test Certificates?
Tell us your IEC grade, cross-section and certificate requirements. Ex-stock EPR Trailing Rubber Cable ready for Riyadh, Jeddah, Jubail and Dammam.
Get Certified QuoteDiscover Trailing Electrical Cables Online With Different Bending Radius and Voltage Rating
Trailing Rubber Electrical Cables Bending Radius
When Equipment Moves Trailing Rubber Cable Bend Every Time, Bending Too Tight Damages The Conductor Strands Over Time. To Avoid Wire Breaks And Insulation Cracks Always Follow The Minimum Bending Radius
| H/05 to VDE 0282 300/500V | Weight Approx Kg/1000m | Outer Diamiter | Amps Per Core | Gland | |
|---|---|---|---|---|---|
| Section mm2 | 25°C | 30°C | |||
| 3 x 1,0 | 87 | 7.8 | 17.85 | 17 | PG9 |
| 3 x 0,75 | 75 | 7.3 | 14.7 | 14 | PG9 |
| 4 x 1,5 | 165 | 9.9 | 22.05 | 21 | PG9 |
| 3 x 1,5 | 135 | 9.5 | 22.05 | 21 | PG9 |
| 4 x 2,5 | 235 | 12.4 | 31.5 | 30 | PG11 |
| H/07 to VDE 0282 450/750V | Weight Approx Kg/1000m | Outer Diamiter | Amps Per Core | Gland | |
| Section mm2 | 25°C | 30°C | |||
| 1 x 50 | 720 | 18 | 212 | 202 | PG21 |
| 1 x 35 | 520 | 16 | 170 | 162 | PG21 |
| 1 x 70 | 940 | 21 | 262 | 250 | PG29 |
| 1 x 120 | 1510 | 25 | 370 | 353 | PG29 |
| 1 x 95 | 1220 | 23 | 316 | 301 | PG29 |
| 1 x 150 | 1850 | 28 | 410 | 391 | PG29 |
| 3 x 4 | 310 | 15 | 43 | 41 | PG16 |
| 3 x 2,5 | 235 | 13 | 31.5 | 30 | PG16 |
| 3 x 6 | 400 | 17 | 55 | 53 | PG21 |
| 3 x 16 | 1000 | 25 | 104 | 99 | PG29 |
| 3 x 10 | 810 | 22 | 77 | 74 | PG29 |
| 3 x 25 | 1470 | 30 | 137 | 131 | PG36 |
| 4 x 2,5 | 280 | 14 | 31.5 | 30 | PG16 |
| 3 x 35 | 1950 | 34 | 170 | 162 | PG42 |
| 4 x 4 | 380 | 17 | 43 | 41 | PG21 |
| 4 x 10 | 940 | 24 | 77 | 74 | PG29 |
| 4 x 6 | 510 | 19 | 55 | 53 | PG21 |
| 4 x 16 | 1250 | 27 | 104 | 99 | PG29 |
| 4 x 35 | 2310 | 36 | 170 | 162 | PG42 |
| 4 x 25 | 1850 | 32 | 137 | 131 | PG36 |
| 4 x 50 | 3160 | 41 | 212 | 202 | PG48 |
| 5 x 2.5 | 340 | 15 | 23.6 | 22.5 | PG16 |
| 4 x 70 | 4250 | 46 | 262 | 250 | PG48 |
| 5 x 4 | 470 | 18 | 33.3 | 30.75 | PG21 |
| 7 x 2.5 | 464 | 20 | 20.5 | 19.5 | PG29 |
| 7 x 1.5 | 316 | 17 | 14.3 | 13.65 | PG16 |
| 7 x 4 | 680 | 23 | 27.98 | 26.65 | PG36 |
| 24 x 1.5 | 980 | 28 | 8.82 | 8.4 | PG36 |
| 8 x 1.5 | 350 | 16 | 12.13 | 11.55 | PG29 |
| 7 x 6 | 808 | 26 | 36.17 | 34.45 | PG36 |
| 8 x 2.5 | 510 | 19.2 | 20.5 | 19.5 | PG29 |
| 12 x 2.5 | 745 | 24 | 17.37 | 16.55 | PG29 |
| 12 x 1.5 | 600 | 22 | 12.13 | 11.55 | PG29 |
| 19 x 2.5 | 1250 | 30 | 14.18 | 13.5 | PG36 |
| 24 x 2.5 | 1480 | 34 | 12.6 | 12 | PG42 |
What Are The Reasons Of Trailing Cable Fail? Know How to Troubleshoot It ?
Strands snap at tight bend points.
Desert UV splits unprotected sheath.
Hydraulic oil swells non-rated sheath.
Wrong voltage rating breaks insulation.
Dragging wears sheath, lets moisture in.
Trailing Rubber Cable Voltage Rating
When Buying Trailing Cable Choosing The Right Voltage Rating Is The Most Important Step . A Mismatched Cable On KSA's 380v Or 11kv Systems Creates Safety Risks and Voids The Warranty
| Voltage Rating | Cable Rating | Phase | Insulation Thickness | Grade | Sheath Recommended |
|---|---|---|---|---|---|
| 380V / 415V | 0.6/1 kV | 3-Phase | 1.2-1.6 mm | 241.1 or 241.2 | PCP Standard |
| 240V | 0.6/1 kV | Single Phase | 1.2-1.6 mm | 241.1 | PCP or CSP |
| 6.6 kV | 3.8/6.6 kV | 3-Phase | 5.5 mm | 241.3 | Heavy CSP |
| 3.3 kV | 1.9/3.3 kV | 3-Phase | 3.4 mm | 241.2 | CSP + PCP |
| 11 kV | 6.35/11 kV | 3-Phase | 7.0 mm | Special Mining | Heavy CSP + Armour |
Test Certificates Required When Buying Trailing Cables for Saudi Projects?
Saudi Aramco, SABIC and NEOM Require Specific Certificates Before Approving Any Trailing Rubber Cable Order. Knowing Which Documents are Needed Upfront Avoids Delays At Site Inspection.
- Routine Test Certificate (RTC)
- Type Test Certificate (TTC)
- Third Party Inspection (TPI)
- Flame Test Certificate
- Halogen Content Certificate
- Country of Origin Certificate
- Drum Packing Specification
- Heat & Lot Traceability Record
Trailing Rubber Cables Delivery Lead Time to Dammam
Trailing Copper Cable vs Aluminium Conductor
- Without Fracturing Flexes
- Lighter Drum Because Of Smaller Diameter
- Standard Lugs, Easy Termination
- Approved Under IEC 60245
- Cracks On Reel Drum Cycles
- Salt-air Corrodes Joints Fast
- Larger Cross-section, No Weight Gain
- Not on Aramco Approved List
Find Trailing Rubber Cable Dealers and Distributors in Saudi Arabia
- Saudi Cable Company, Jeddah
- Al-Babtain Power & Telecom, Dammam
- Tamimi Markets & Industrial Supplies, Riyadh
- National Electrical Industries, Al Jubail
- Al Othman Trading & Contracting, Dammam
- Riyadh Cables Group, Riyadh
- Gulf Cable & Electrical Industries, Kuwait (KSA stock)
- Arabian Electrical Industries, Jeddah
- Al-Khobar Electrical Materials, Al Khobar
Related Flexible Rubber Cable Available in Ex.Stock
Flexible Welding Cables
- 16 mm² to 95 mm²
- Fine stranded copper
- Rubber insulated
- IEC 60245-6
Festoon Flat Trailing Cable
- 2 to 24 cores
- Flat profile for festoon systems
- PVC or PCP sheath
- Crane overhead systems
Heat Resistant Silicone Cable
- Up to +180°C rating
- Silicone rubber insulation
- Fine wire Cu conductor
- Furnace & oven trailing
Armoured Rubber Cable
- SWA or SWB armour
- EPR insulated cores
- Mining & outdoor use
- IEC 60502 / BS 6708
Composite Control Trailing
- Power + control + pilot
- Individual core screens
- EPR insulated all cores
- PCP / CSP dual sheath
Submersible Pump Trailing
- Waterproof construction
- EPR insulated 3-core
- 0.6/1kV rating
- Dewatering pump systems
| 60°C Thermoplastic or Thermosetting Insulated Cords: | ||||||
|---|---|---|---|---|---|---|
| Correction Factor: | 0.91 | 0.82 | 0.71 | 0.58 | 0.41 | |
| Ambient Temperature: | 35°C | 40°C | 45°C | 50°C | 55°C | |
| 90°C Thermoplastic or Thermosetting Insulated Cords: | ||||||
| Correction Factor: | 1.0 | 0.96 | 0.83 | 0.67 | 0.47 | |
| Ambient Temperature: | 35°C to 50°C | 55°C | 60°C | 65°C | 70°C | |
| 180°C Thermosetting Insulated Cords: | ||||||
| Correction Factor: | 1.0 | 0.96 | 0.85 | 0.74 | 0.60 | 0.42 |
| Ambient Temperature: | 35°C to 120°C | 125°C | 130°C | 135°C | 140°C | 145°C |
| Glass Fibre Cords: | ||||||
| Correction Factor: | 1.0 | 0.92 | 0.82 | 0.71 | 0.51 | 0.40 |
| Ambient Temperature: | 35°C to 150°C | 155°C | 160°C | 165°C | 170°C | 175°C |
Send Your Trailing Rubber Cable Specifications via Email and Get Quotes Today
Email Your Trailing Cable Specs Like Size, Cores, Voltage, Quantity And Certificate To contact@pipingmaterial.sa. We Will Instantly Match You With Verified Trailing Rubber Cable Stockists in Saudi Arabia Who Have Your Exact Requirement Ready.
Get Free Quote| conductor Cross-section | mm2 | 4 × 95 | 4 × 70 |
|---|---|---|---|
| mm² per conductor and cores number | OD in mm | Weight in kg/km | Copper Weight in kg/km |
| 4 G 2.5 | 12.1 - 15.5 | 235 | 96 |
| 3 G 2.5 | 10.9 - 14 | 185 | 72 |
| 7 G 2.5 | 17.1 - 21.8 | 520 | 168 |
| 5 G 2.5 | 13.3 - 17 | 290 | 120 |
| 4 G 6.0 | 15.7 - 20 | 440 | 230.4 |
| 5 G 4.0 | 15.6 - 19.9 | 410 | 192 |
| 4 G 50.0 | 37.7 - 47.5 | 2810 | 1920 |
| 4 G 16mm | 23.8 - 30.1 | 1070 | 614.4 |
| 5 G 6.0 | 17.5 - 22.2 | 550 | 288 |
| 4 G 25.0 | 28.9 - 36.6 | 1570 | 960 |